IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues. 

 
 

Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts for 
a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for proof of 
purchase, purchase date and dealer or distributor.  If purchase date can not be provided, warranty period 
will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace parts or 
equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, belts, 
power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items or any 
problem resulting from the following: improper wiring, incorrect voltage (including low or over voltage 
conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage resulting 
from shipping.  Warranty will be null and void if the product is altered, modified, misused, damaged, or 
subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. This warranty 
gives you specific legal rights, and you may also have other rights which vary from state to state.  Any 
liability for consequential and incidental damages is expressly disclaimed.  No other warranty, expressed 
or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the purchase 
price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect. 

  

 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 

Model Number: DM-VECTORLED712QB 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 

www.Techni-Lux.com 
10900 Palmbay Drive 

Orlando, FL 32824 

U.S.A. 

Summary of Contents for VectorLED Series DM-VECTORLED712QB

Page 1: ...Information specifically for DM VECTORLED712QB V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...ceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directl...

Page 3: ...ction 8 LED Engine 8 Mounting 9 Control Panel 10 Control Panel Indicators 10 Control Panel Display 10 Control Panel Menu 11 DMX 512 Start Address 12 DMX 512 Channel Assignment 13 6 Channel Mode 13 13...

Page 4: ...ining lenses for smooth and even color mixing Digital dimming 0 100 for smooth fades and even field Electronic strobe with pulse or random effects DMX512 Control using 6 13 or 37 channels 3 pin In Out...

Page 5: ...l Selectable Voltages Auto Switching 110 240v 50 or 60Hz Connection IEC C13 Power Inlet with Fuse Rated Power 150W 1 5A 115v Fuses 5A Fast Blow Size 5x20mm Control Protocol USITT DMX512 1990 Channels...

Page 6: ...6 Unit Parts 1 Head 2 Yoke 3 Base 4 Control Panel 5 Base Bottom 6 Omega Clamp Adapter 1 2 3 4 5 6...

Page 7: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Page 8: ...m a switched circuit This fixture cannot be run on rheostat or dimmer circuits even if used solely for a 0 to 100 switching Consult a qualified electrician if there are any concerns about proper conne...

Page 9: ...propriate clamp and a safety cable Safety cables must always be attached to the fixture Do not use handles as mounting points Do not mount in a place where the fixture will be exposed to rain high hum...

Page 10: ...ubsequent power cycles The MENU button also moves back in the menu The display can be set to turn off after 60 seconds of inactivity Control Panel Indicators LED Function DMX DMX detected flashing whe...

Page 11: ...Reverse Pan Direction YES Y revers NO Reverse Tilt Direction YES XYtrade NO Swap Pan and Tilt Control XY fast XY norm XYspeed XY slow Pan Tilt motor speed YES XYfbsti NO Enable Pan Tilt Position Auto...

Page 12: ...annels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved together and r...

Page 13: ...nel Mode Channel Function 1 Shutter Strobe 2 Dimmer 3 Pan 4 Pan Fine 5 Tilt 6 Tilt Fine 7 Pan Tilt Speed 8 LED control Reset 9 Color Macro 10 LED Position 1 Red 11 LED Position 1 Green 12 LED Position...

Page 14: ...lse fast slow 205 209 Shutter open 210 224 Strobe 9 sine wave fast slow 225 229 Shutter open 230 244 Strobe 10 random burst fast slow 1 1 245 255 Shutter open Dimmer 0 244 Closed to Open does not affe...

Page 15: ...E 104 Deep Amber 145 149 LEE 179 Chrome Orange 150 154 LEE 105 Orange 155 159 LEE 021 Gold Amber 160 169 LEE 778 Millennium Gold 170 174 LEE 164 Flame Red 175 179 ALL RGBW LEDS ON Color Effects overri...

Page 16: ...LED 4 Red 23 0 255 LED 4 Green 24 0 255 LED 4 Blue 25 0 255 LED 4 White 26 0 255 LED 5 Red 27 0 255 LED 5 Green 28 0 255 LED 5 Blue 29 0 255 LED 5 White 30 0 255 LED 6 Red 31 0 255 LED 6 Green 32 0 2...

Page 17: ...s handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connec...

Page 18: ...then connect pin 2 to pin 2 and pin 3 to pin 3 This is true for converting either 5 to 3 pin or 3 to 5 pin regardless of either connector s gender Pins 4 and 5 are not used on the 5 pin XLR connector...

Page 19: ...ol Any cleaner approved for coated eyeglass lenses will also work 5 Inspect clamps and safety cables to ensure fixture is secure and safe Troubleshooting Symptom Possible Cause Solution Check power sw...

Page 20: ...e made 1 3 pin XLR Cable CA XLR3 5 Pre made 5 3 pin XLR Cable CA XLR3 10 Pre made 10 3 pin XLR Cable CA XLR3 25 Pre made 25 3 pin XLR Cable CA XLR3 50 Pre made 50 3 pin XLR Cable CA XLR3 100 Pre made...