Techni-Lux VectorLED Series DM-VECTORLED712QB Manual Download Page 15

 

15

6 Ch 

Compact 

13 Ch 

Standard 

37 Ch 

Extended DMX 

Value 

Function 

45-49 

LEE 071-Tokyo blue 

50-54 

LEE 120-Deep Blue 

55-59 

LEE 079-Just Blue 

60-64 

LEE 132-Medium Blue 

65-69 

LEE 200-Double CT Blue 

70-74 

LEE 161-Slate Blue 

75-79 

LEE 201-Full CT blue 

80-84 

LEE 202-Half CT BLUE 

85-89 

LEE 117-Steel Blue 

90-94 

LEE 353-Lighter Blue 

95-99 

LEE 118-Light blue 

100-104 

LEE 116-Medium Blue Green 

105-109 

LEE 124-Dark Green 

110-114 

LEE 139-Primary Green 

115-119 

LEE 089-Moss Green 

120-124 

LEE 122-Fern Green 

125-129 

LEE 738-JAS Green 

130-134 

LEE 088-Lime Green 

135-139 

LEE 100-Spring yellow 

140-144 

LEE 104-Deep Amber 

145-149 

LEE 179-Chrome Orange 

150-154 LEE 

105-Orange 

155-159 

LEE 021-Gold Amber 

160-169 

LEE 778-Millennium Gold 

170-174 

LEE 164-Flame Red 

175 - 179 

ALL RGBW LEDS ON 

 

Color Effects – overrides RGBW 

180 – 201 

Color Roll - Clockwise (fast-slow) 

202 - 207 

Stop Color Roll on color 

208 - 229 

Color Roll – Counterclockwise (slow-fast) 

230 - 234 

RGBW Full ON 

235 - 239 

Color Snap Random (fast)  

240 - 244 

Color Snap Random (medium) 

245 - 249 

Color Snap Random (slow) 

 

 

 

250 - 255 

RGBW Full ON 

3 9   0-255 

LED 1-7 Red 

4 10    0-255 

LED 1-7 Green 

5 11    0-255 

LED 1-7 Blue 

6 12    0-255 

LED 1-7 White 

13  

 

Reserved – No Effect 

10 0-255 

LED 1 Red 

11 0-255 

LED 1 Green 

12 0-255 

LED 1 Blue 

13 0-255 

LED 1 White 

14 0-255 

LED 2 Red 

15 0-255 

LED 2 Green 

16 0-255 

LED 2 Blue 

17 0-255 

LED 2 White. 

 

 

18 0-255 

LED 3 Red 

continued 

continued 

Summary of Contents for VectorLED Series DM-VECTORLED712QB

Page 1: ...Information specifically for DM VECTORLED712QB V1 0 This manual contains important information Please read before operating fixture...

Page 2: ...ceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directl...

Page 3: ...ction 8 LED Engine 8 Mounting 9 Control Panel 10 Control Panel Indicators 10 Control Panel Display 10 Control Panel Menu 11 DMX 512 Start Address 12 DMX 512 Channel Assignment 13 6 Channel Mode 13 13...

Page 4: ...ining lenses for smooth and even color mixing Digital dimming 0 100 for smooth fades and even field Electronic strobe with pulse or random effects DMX512 Control using 6 13 or 37 channels 3 pin In Out...

Page 5: ...l Selectable Voltages Auto Switching 110 240v 50 or 60Hz Connection IEC C13 Power Inlet with Fuse Rated Power 150W 1 5A 115v Fuses 5A Fast Blow Size 5x20mm Control Protocol USITT DMX512 1990 Channels...

Page 6: ...6 Unit Parts 1 Head 2 Yoke 3 Base 4 Control Panel 5 Base Bottom 6 Omega Clamp Adapter 1 2 3 4 5 6...

Page 7: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Page 8: ...m a switched circuit This fixture cannot be run on rheostat or dimmer circuits even if used solely for a 0 to 100 switching Consult a qualified electrician if there are any concerns about proper conne...

Page 9: ...propriate clamp and a safety cable Safety cables must always be attached to the fixture Do not use handles as mounting points Do not mount in a place where the fixture will be exposed to rain high hum...

Page 10: ...ubsequent power cycles The MENU button also moves back in the menu The display can be set to turn off after 60 seconds of inactivity Control Panel Indicators LED Function DMX DMX detected flashing whe...

Page 11: ...Reverse Pan Direction YES Y revers NO Reverse Tilt Direction YES XYtrade NO Swap Pan and Tilt Control XY fast XY norm XYspeed XY slow Pan Tilt motor speed YES XYfbsti NO Enable Pan Tilt Position Auto...

Page 12: ...annels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved together and r...

Page 13: ...nel Mode Channel Function 1 Shutter Strobe 2 Dimmer 3 Pan 4 Pan Fine 5 Tilt 6 Tilt Fine 7 Pan Tilt Speed 8 LED control Reset 9 Color Macro 10 LED Position 1 Red 11 LED Position 1 Green 12 LED Position...

Page 14: ...lse fast slow 205 209 Shutter open 210 224 Strobe 9 sine wave fast slow 225 229 Shutter open 230 244 Strobe 10 random burst fast slow 1 1 245 255 Shutter open Dimmer 0 244 Closed to Open does not affe...

Page 15: ...E 104 Deep Amber 145 149 LEE 179 Chrome Orange 150 154 LEE 105 Orange 155 159 LEE 021 Gold Amber 160 169 LEE 778 Millennium Gold 170 174 LEE 164 Flame Red 175 179 ALL RGBW LEDS ON Color Effects overri...

Page 16: ...LED 4 Red 23 0 255 LED 4 Green 24 0 255 LED 4 Blue 25 0 255 LED 4 White 26 0 255 LED 5 Red 27 0 255 LED 5 Green 28 0 255 LED 5 Blue 29 0 255 LED 5 White 30 0 255 LED 6 Red 31 0 255 LED 6 Green 32 0 2...

Page 17: ...s handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connec...

Page 18: ...then connect pin 2 to pin 2 and pin 3 to pin 3 This is true for converting either 5 to 3 pin or 3 to 5 pin regardless of either connector s gender Pins 4 and 5 are not used on the 5 pin XLR connector...

Page 19: ...ol Any cleaner approved for coated eyeglass lenses will also work 5 Inspect clamps and safety cables to ensure fixture is secure and safe Troubleshooting Symptom Possible Cause Solution Check power sw...

Page 20: ...e made 1 3 pin XLR Cable CA XLR3 5 Pre made 5 3 pin XLR Cable CA XLR3 10 Pre made 10 3 pin XLR Cable CA XLR3 25 Pre made 25 3 pin XLR Cable CA XLR3 50 Pre made 50 3 pin XLR Cable CA XLR3 100 Pre made...

Reviews: