background image

 

9

DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for the fixture (see DMX Background).  Before addressing fixtures, consult the manual of the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from 1 to 512.  Fixtures requiring more than one channel for control will read subsequent 
channels up to the total number of channels required.  Since this fixture requires a maximum of 
10 channels of DMX, if set to a Start Address of 11 it would use data from channels: 11, 12, 13, 
14, 15, 16, 17, 18, 19, and 20. Choose a Start Address so the channels used do not overlap 
with other fixtures.  In some cases, it may be desirable to set two or more same type fixtures to 
the same Start Address.  In this case, the fixtures will be slaved together and respond to the 
same data.  Because all fixtures see the same data, fixtures may be set to any address without 
concern for the order they are connected by the DMX cables.   
 

 

DMX Data Connection 

This fixture uses 3 pin or 5 pin XLR type connectors. For data use shielded twisted pair 
cable approved for EIA-422/EIA485 use.  Fixtures are connected in Daisy Chain 
topography:  Connection is made from the controller to the DMX-IN of the first light, then 
from the DMX-OUT to the DMX-IN of the next light and so on.  Only one data source can 
be on a chain and no branching is allowed.  The physical order in which the fixtures are 
connected is not important, use the most convenient.  

 
 
 
 
 
 
 
 

 

Data Terminator 

A Data Terminator can be connected to the DMX-OUT of the last fixture 
to reduce the effects of signal noise; it is not required for all installations. 
To make a Terminator, connect a 120-ohm ¼ watt resistor across pin 2, 
Data Negative (S-) and pin 3, Data positive (S+). A qualified technician 
can determine if a Data Terminator is needed. 

 

Adapter

 

5-to-3 pin 

Systems using 5 pin DMX interfaces can be accommodated by purchasing 3-to-5 pin 
adapters or building adapter cables.  Numbers designating each pin can be found on 
connectors.  Converting between the two XLR types is done in a pin-to-pin fashion.   
Connect the shields to pin 1, then connect pin 2 to pin 2 and pin 3 to pin 3, regardless of 
either connector’s gender or pin count.  No connection is made to Pins 4 & 5. 
 
 
 
 

DMX-OUT

1

- Ground

- Signal (-)
- Signal (+)

XLR Connector - Socket:

 

DMX-IN



- Ground
- Signal (-)
- Signal (+)

XLR Connector - Plug:

Summary of Contents for UltraLux DL-ULTRALUX7C6

Page 1: ...Information specifically for DL ULTRALUX7C6 Black with RGBWAUV LEDS V1 1 This manual contains important information Please read before operating fixture ...

Page 2: ...ited to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompan...

Page 3: ...ng Diagrams 7 Operating Setting Buttons 7 Fixture Menu LED Display 8 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 9 Adapter 5 to 3 pin 9 DMX Start Address 10 DMX Channel Assignments 10 6 Channel Mode 11 10 Channel Mode 11 Maintenance 12 Accessory Items sold separately 12 Troubleshooting 13 DMX 512 Background 14 ...

Page 4: ...bs 3 5 kgs Housing Material Aluminum Environmental Location Indoor IP20 Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 90 250vAC 50 60Hz Connection PowerCon In and Pass Thru Rated Power 72W Fuses Internal 2 amp mini 5mm x 20mm Rating Approval CE Control Digital Protocol USITT DMX512 1990 Cha...

Page 5: ...ide the model number serial number and description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and t...

Page 6: ...there is adequate room for movement and ventilation Mount the fixture securely using the two mounting holes provided on both sides of the base This fixture features an adjustable base which allows the panel to be tilted at different desired angles Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixture will be exposed to heavy wat...

Page 7: ...iring is explained in more detail in the DMX Data Connection section of this manual Example Block Diagram Operating Setting Buttons The following refers to the settings that are available on this fixture via the LED Segment Control Panel display All functions are selectable from the display menu located at the back of the fixture using the four push buttons Menu Up Down Enter Press MENU to return ...

Page 8: ...nctions 001 512 6 channels 001 512 10 channels 00 99 Color Fade in out slow fast 00 99 Color changing slow fast 00 99 Color selective 000 255 Red intensity 000 255 Green intensity 000 255 Blue intensity 000 255 White intensity 000 255 UV intensity 000 255 Amber intensity Demo Auto run Sound Active Mode Delayed off Delayed on 1 3 fast slow ...

Page 9: ...elded twisted pair cable approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the next light and so on Only one data source can be on a chain and no branching is allowed The physical order in which the fixtures are connected is not important use the most conven...

Page 10: ...e will leave no empty channels between fixtures so the second Start Address is set to DMX channel 11 and that fixture occupies channels 11 thru 20 The third fixture will be addressed 11 10 21 and occupy channels 21 thru 30 The last fixture is addressed 21 10 31 and will occupy channels 31 thru 40 Thus 4 fixtures using 10 channels each have Start Addresses of 1 11 21 and 31 and the next free channe...

Page 11: ...sity 0 255 4 G Green intensity 0 255 5 B Blue intensity 0 255 6 W White intensity 0 255 7 UV UV intensity 0 255 8 A Amber intensity 0 255 9 Marco No effect 0 9 R 10 34 R G R same G bright 35 64 G B G bright R less brighter 65 94 G 95 97 G B G same B brighter 98 127 G B B same G less brighter 128 157 B 158 160 B R B same R brighter 161 190 R G B R and B are same G brighter 191 225 R G B W A R G and...

Page 12: ...e care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description TA BDR UL7 4 Leaf Barndoor Black CL CBHALF Half Cheese borough Coupler 300kg Max Load CL...

Page 13: ...d proper wiring Check Display settings Check Start Address Incorrectly responds to DMX Diagnostic technique for DMX issues Set suspect fixture s Start Address the same as a correctly functioning fixture If both units then function correctly issue is programming Check Start Address Check for overlapping addresses Check Menu settings Check Data cables faults and proper wiring ...

Page 14: ...arent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connected using a Daisy Chain connection The signal is jumped from the controller to a piece of DMX equipment From there the signal is jumped to the next piece of equipment and so on ...

Page 15: ...15 ...

Page 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com ...

Reviews: