Troubleshooting
Symptom
Possible Cause / Solution
Check for power on mains
Check power switch
Check main fuse and fuse holder
No Power
Check data cables
Check Start Address
Check that fixture isn’t in the Demo mode
No response to DMX
Check Start Address
Check for overlapping addresses
Check fixture set up (Pan/Tilt Invert…)
Check Data cables (faults and proper wiring)
Incorrectly responds to DMX
(Diagnostic technique for DMX issues: Set
suspect fixture’s Start Address the same as a
correctly functioning fixture. If both units then
function correctly, issue is programming)
Bad or end of life lamp
Check DMX value for Control/Reset Lamp
Channel
Inspect fixture light path and verify no effects
are blocking beam
Remove from DMX and check to see if lamp
can be struck from Control Panel
Over temperature error – Tun Lamp off and
allow fixture to cool then attempt to restrike
the lamp. If this is the case, check all fans.
No Lamp Power
See “Incorrectly responds to DMX”
Check for properly wired DMX cables
Check for broken wires inside unit
Check for damaged Data transceiver IC.
Erratic operation
Check sensor and magnet
Check belts (if applicable)
Check motor with no power, should be able
to move easily.
An effect wheel doesn’t go to correct position
22
Summary of Contents for IL-TRACKER575W/1
Page 2: ...2005 Techni Lux Inc 2...