IMPORTANT INFORMATION 

 
 

Save original packing and documentation for warranty, service and return issues. 

 
 

Limited Warranty: 

This warranty covers defects or malfunctions in this equipment.  This warranty lasts 

for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 

Returning equipment and Repairs: 

 All returns must be accompanied by a Return Merchandise 

Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee of 20%.  No returns accepted on discontinued 
items.  Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse 
any return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 

Claims:

  All claims must be made within seven (7) days of receipt of merchandise.  Any physical 

damage must be reported to carrier upon receipt of merchandise. 
 

 

Please record the following information for future reference: 

 

Model Number: IL-TRACKER575W/1 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 

www.Techni-Lux.com 

10779 Satellite Boulevard 

Orlando, FL 32837 

U.S.A. 

 

3

Summary of Contents for IL-TRACKER575W/1

Page 1: ...In IL TRACKER575W 1 formation specifically for V1 2 This manual contains important information Please read before operating fixture...

Page 2: ...2005 Techni Lux Inc 2...

Page 3: ...purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obt...

Page 4: ...tor 12 Adapter 5 to 3 pin 12 Control Panel Menu 13 Start Address 13 Example 13 DMX 512 Channels 14 CH 1 4 Pan Tilt Movement 14 CH 5 Movement Speed Pan Tilt 14 CH 6 Control Reset Lamp 15 CH 7 Fixed Col...

Page 5: ...le shutter for strobe effects and quick blackouts Motorized dimmer from 0 to 100 Control via DMX512 using 3 pin In Out XLRs Uses 16 Channels of DMX Digital display for DMX addressing and fixture setti...

Page 6: ...er 850W 7A 120v Fuses 15A Time Delay Slow Size x 1 Control Protocol USITT DMX512 1990 Channels 16 Pan Tilt Resolution16 bit Data I O 3 Pin XLR Cannon Modes Master Slave DMX Optics Reflector High effic...

Page 7: ...ts Front panel 10 Mode button 11 Enter button 12 Up button 13 Down button 14 Display Rear panel 5 Power switch 6 DMX output 7 DMX input 8 Power cord 9 Fuse holder 1 Moving head 2 Yoke 3 Carry handles...

Page 8: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Page 9: ...tches the power source voltage Consult a qualified electrician if there are any concerns about proper connection to power Pin Cable EU International Brown Light blue ellow Green Y Black White Green Li...

Page 10: ...e maximum possible life As Discharge lamps age the glass envelope becomes weaker increasing the chance of failure due to the high internal pressures Rupture could result in damage to the fixture and o...

Page 11: ...the projected beam is as evenly bright as possible 3 adjustment screws A B C Mounting Always consult a qualified professional when rigging This fixture may be placed on any flat surface or truss that...

Page 12: ...installations To make a Data Terminator connect a 120 ohm watt resistor across pin 2 Data Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adap...

Page 13: ...tart Address of eleven 11 would read data from channels 11 and 12 13 14 15 The next logical Start Address would be channel 16 Because all fixtures see the same data fixtures may be set to any address...

Page 14: ...ct automatically The Pan and Tilt Menu Modes can be used to alter the default direction of movement Movement speed is either automatically determined by the fixture or manually set using Channel 5 Pan...

Page 15: ...27 No Function 128 139 RESET then Lamp ON 3 second delay 140 229 No Function 230 239 Lamp OFF 3 second delay 240 255 No Function CH 7 Fixed Color Wheel The Fixed Color Wheel holds 4 solid colors 2 col...

Page 16: ...ther CMY channels and the Fixed Color Wheel to create many color combinations CH 9 Magenta Mix DMX Value Function 0 255 Magenta Saturation Least to Most CH 10 Yellow Mix Controls the saturation of the...

Page 17: ...7 Color Preset 11 168 181 Color Preset 12 182 195 Color Preset 13 196 209 Color Preset 14 210 223 Color Preset 15 224 237 Color Preset 16 238 251 Color Preset 17 252 255 Color Preset 18 CH 13 Effects...

Page 18: ...the shutter at irregular intervals CH 15 Shutter DMX Value Function 0 31 Closed Black Out 32 63 Open 64 95 Strobe Effect Slow to Fast 96 127 Open 128 131 Pause 132 159 Pulse Strobe Effect Slow to Fast...

Page 19: ...Photometric Charts 19...

Page 20: ...andled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connected...

Page 21: ...nics mechanical elements reduce lamp life fixture life and over all performance Before conducting any maintenance disconnect fixture from power mains 1 Disconnect fixture from power mains 2 Use a vacu...

Page 22: ...ts then function correctly issue is programming Bad or end of life lamp Check DMX value for Control Reset Lamp Channel Inspect fixture light path and verify no effects are blocking beam Remove from DM...

Page 23: ...Fan TILT ENCODER SENSOR PAN SENSOR TILT SENSOR DIMMER STROBE SPIRAL LENS 1 SPIRAL LENS 2 RIPPLE LENS 2106L SPIRAL LENS ZOOM SENSOR RIPPLE LENS SENSOR IGNITER BALLLEST TEMPERATURE SWITCH POWER SUPPLY F...

Page 24: ...18 SAFETYCABLE4 Safety Cable Silver 18 CA XLR3 1 Pre made 1 3 pin XLR Cable CA XLR3 5 Pre made 5 3 pin XLR Cable CA XLR3 10 Pre made 10 3 pin XLR Cable CA XLR3 20 Pre made 20 3 pin XLR Cable CA XLR3...