Alarm Indicator status
Common Faults
Trouble Shooting
LSR2 is amber
The same as lLSR1 is Amber”
The same as lLSR1 is Amber” m
LSR2 is red
The same as lLSR1 is red”
The same as lLSR1 is red” s
STAT is amber
Operating environment Temperature is
lower or higher.
Check the fans, or lower the room
temperature. If the temperature is normal,
please contact Technetix technical support.
+12V /+5V /-5VInput Voltage is lower or
higher.
Please contact Technetix technical support.
RF input is lower or higher.
Adjust input signal or adjust MGC to an
appropriate value.
Laser Warning ALM or
Laser shutdown.(“Laser Output Status
Alarm ”is set “enableMinor”)
Check the laser’s status.
STAT is red
Operating environment Temperature is
too high or too low.
Check the Fans, or lower the room
temperature. If the temperature is normal,
please contact Technetix technical support.
+12V /+5V/-5V Input Voltage too high or
too low.
Please contact Technetix technical support.
RF input power too high or too low.
Adjust input signal or adjust MGC to an
appropriate value.
Laser Critical ALM or Laser shutdown.
(“Laser Output Status Alarm ”is set
“enableMajor”)
Check the laser’s status.