6.1.6 Input / Output Status Monitoring
To setup Input / Output status monitoring, select the either
“Port 1”
,
“Port 2”
,
"Port 3”
, and
“Port 4”
from the left menu, and
then the monitoring parameters will be listed for the designated transmitter under the
“Alarm Settings”
section, click on ☑
to toggle the alarms. The customer can not change the monitoring parameters. All transmitters have independent settings
and they need to be adjusted separately.
See Figure 6-8
.
Figure 6-8
Table 6 3 Port Page Alarms Threshold Parameters Instruction
Parameter
Units
HIHI
HI
Normal
LO
LOLO
Dead
Band
Threshold
changeable by
user
Default Alarm
Enable
RF Input power
dBmV
46.4
41.4
-
25.4
20.4
1
Y
ON
Laser Temperature
oC
57
54
-
25
20
0.5
Y
ON
Laser Case Temperature
oC
78
73
-8
-13
2.0
Y
ON
Laser Bias Current
mA
80
75
-
20
15
2
Y
ON
Laser Output Power
dBm
8
7
-
5
4
0.3
Y
ON