Working environment 

The calibrator units are designed to work safely under the following conditions: 
 

Ambient temperature range:   5°C/9°F to 40°C/104°F 

 Humidity:   Up to 95% relative humidity, non-condensing 

Warning 

Warning:  

HIGH TEMPERATURES ARE DANGEROUS 

Avertissement:   DANGER DE TEMPERATURES ELEVEES 

Warnung:  

HOHE TEMPERATUREN SIND GEFÄHRLICH 

Aviso:    

LAS TEMPERATURAS ELEVADAS SON PELI 

 

 

HIGH TEMPERATURES ARE DANGEROUS:  They can cause serious burns to operators and ignite combustible 

material.  Techne has taken great care in the design of these units to protect operators from hazards, but 
operators should pay attention to the following points: 

 

• USE CARE AND WEAR PROTECTIVE GLOVES TO PROTECT HANDS 

• DO NOT put hot objects on or near combustible objects 
• DO NOT operate the unit close to inflammable liquids or gases 

• DO NOT place any liquid directly in your unit 
• At all times USE COMMON SENSE 

 

Operator Safety 

All operators of Techne

®

 equipment must have available the relevant literature needed to ensure their safety. It 

is important that only suitably trained personnel operate this equipment in accordance with the instructions 
contained in this manual and with general safety standards and procedures. If the equipment is used in a manner 

not specified by Techne, the protection provided by the equipment to the operator may be impaired. All Techne

®

 

units have been designed to conform to international safety requirements and are fitted with a preset over-

temperature cutout. If a safety problem is encountered, switch off at the mains socket and remove the plug from 
the supply. 

-3- 

Summary of Contents for UCAL400+

Page 1: ...UCAL400 Calibrator OPERATOR S MANUAL Please read all the information in this booklet before using the unit Unit Serial number _________ 4 02 Issue 1 TECHNE is a registered Trademark of Techne Incorpo...

Page 2: ...aluminum insert block as the heat transfer medium The temperature control circuit is built into the unit Features include 10 insert formats available Maximum temperature of 430 C 806 F An independent...

Page 3: ...y 0 015 C 0 025 C Heat up time 20 C to 400 C 12 minutes Cool down 400 C to 100 C 21 minutes Immersion Depth 4 5 114 3mm Fan Cooling Automatic Weight 9 lbs 4 Kg Dimensions H x W x D 8 75 x 8 x 8 inches...

Page 4: ...NDS DO NOT put hot objects on or near combustible objects DO NOT operate the unit close to inflammable liquids or gases DO NOT place any liquid directly in your unit At all times USE COMMON SENSE Oper...

Page 5: ...following value fuse to protect the cable 230V UK 4 AMP The fuse in the unit protects the unit and the operator Note that units marked 230V on the rating plate work at 220V units marked 120V work at...

Page 6: ...ol circuit give good temperature control and uniformity but make sure that there is a close fit of the probes in the block to allow efficient heat transfer 2 Plug the power cable into the socket in th...

Page 7: ...T NOT BE SET TO CONTROL ABOVE 430 C 806 F OR DAMAGE TO THE UNIT MAY RESULT After use 1 When you have finished calibrating remember that parts of the unit and the probe may be very hot so precautions s...

Page 8: ...eaning Before cleaning your unit ALWAYS disconnect it from the power supply and allow it to cool below 50 C Your unit can be cleaned by wiping with a damp soapy cloth Care should be exercised to preve...

Page 9: ...vailable inserts Part Number Insert well Sizes 7022533 insert 5 x 1 4 7032534 insert 1 each 1 8 3 16 1 4 5 16 3 8 7032535 insert 2 x 1 4 2 x 3 8 7032536 insert 2 x 1 4 2 x 1 2 7032537 insert 1 x 1 4 7...

Page 10: ...card This period is from the date of purchase and within this period all defective parts will be replaced free of charge provided that the defect is not the result of misuse accident or negligence Se...

Reviews: