6.10.2 Zone Antipassback
The
Zone Antipassback
is defined by
enabling the option
for the relevant address. The
Zone APB flag is set for the ID when passing at the reader module. If a user uses the ID
again when the Zone APB flag is set, the Zone APB alarm is raised. Following parameters
affect the Zone APB function:
Enabled
– enable/disable general Zone APB flag setting.
Enable in offline mode
– if the option is not set, the module operates in offline mode
like if the APB function was not implemented.
Open door after APB Zone alarm
– if the option is enabled, the Door open function is
performed after the Zone APB alarm is raised.
Set opposite APB flag after APB alarm
– if the Zone APB alarm is raised, the Zone
APB alarm flag is set for both directions (entry reader and the module itself) of the
module.
Clear opposite APB flag
– if the option is enabled, passing at the reader module
causes a reset of the Zone APB alarm flag at the opposite direction.
6.11
Disabling function
This function is implemented since the
FW version 5.08
.
The
module disabling function
can be set at the second input and at the third input / output
port. The logic of the function is individually configurable. The function is active whenever
one or both of the configured inputs are active.
The module behavior is as described below when the disabling function is active:
User with access driven by a time schedule cannot run the door open function
User with access always granted is not affected by the disabling function
Remote door open function cannot be performed
Remote identification with ID is disabled for users with access driven by a time
schedule
The disabling status changes and disabled actions are logged in the events archive.
6.12
Reading synchronization
Since the
FW version 5.09
the reading synchronization of a
couple of TECHFASS readers
is implemented, enabling to
cancel the mutual disturbance
of the modules. The reader
module offers to use the
IO synchronization
in both
MASTER
and
SLAVE
mode. The
input/output port 3
is used as the
synchronization signal
.
6.13
Online authorization
Since the
FW version 5.11
the
Online authorization of ID
can be used in APS mini Plus
system. When the feature is used, the ID validity is resolved in connected PC. To be able
to use this authorization mode, the reader module has to be equipped with a
MLO
license.