6.10.2  Zone Antipassback 

The 

Zone  Antipassback

  is  defined  by 

enabling  the  option

  for  the  relevant  address.  The 

Zone APB flag is set for the ID when passing at the reader module. If a user uses the ID 
again when the Zone APB flag is set, the Zone APB alarm is raised. Following parameters 
affect the Zone APB function: 

 

Enabled 

– enable/disable general Zone APB flag setting. 

 

Enable in offline mode 

– if the option is not set, the module operates in offline mode 

like if the APB function was not implemented. 

 

Open door after APB Zone alarm 

– if the option is enabled, the Door open function is 

performed after the Zone APB alarm is raised. 

 

Set opposite  APB flag after  APB  alarm 

–  if  the Zone  APB  alarm  is  raised,  the  Zone 

APB  alarm  flag  is  set  for  both  directions  (entry  reader  and  the  module  itself)  of  the 
module. 

 

Clear  opposite  APB  flag

  –  if  the  option  is  enabled,  passing  at  the  reader  module 

causes a reset of the Zone APB alarm flag at the opposite direction. 

6.11 

Disabling function 

This function is implemented since the 

FW version 5.08

The 

module disabling function

 can be set at the second input and at the third input / output 

port. The logic of the function is individually configurable. The function is active whenever 
one or both of the configured inputs are active. 

The module behavior is as described below when the disabling function is active: 

 

User with access driven by a time schedule cannot run the door open function 

 

User with access always granted is not affected by the disabling function 

 

Remote door open function cannot be performed 

 

Remote  identification  with  ID  is  disabled  for  users  with  access  driven  by  a  time 
schedule 

The disabling status changes and disabled actions are logged in the events archive. 

6.12 

Reading synchronization 

Since the 

FW version 5.09

 the reading synchronization of a 

couple of TECHFASS readers 

is  implemented,  enabling  to 

cancel  the  mutual  disturbance

  of  the  modules.  The  reader 

module  offers  to  use  the 

IO  synchronization

  in  both 

MASTER

  and 

SLAVE

  mode.  The 

input/output port 3

 is used as the 

synchronization signal

6.13 

Online authorization 

Since  the 

FW  version  5.11

  the 

Online  authorization  of  ID

  can  be  used  in  APS  mini  Plus 

system. When the feature is used, the ID validity is resolved in connected PC. To be able 
to use this authorization mode, the reader module has to be equipped with a 

MLO

 license. 

 

 

 

Summary of Contents for MREM 79

Page 1: ...dules for Fermax Cityline and Fermax Skyline entry panels User s guide 2004 2014 TECH FASS s r o Věštínská 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of release 2014 5 15 valid for FW version 5 11 ...

Page 2: ...ection 6 4 3 Installation instructions 7 4 4 Assembly and disassembly of the reader module 7 5 Setting parameters of the reader module 8 5 1 Configurable parameters 8 5 2 Reader module parameters setting 8 6 Reader module functioning 9 6 1 Door Open function description 9 6 2 Function permanent door lock release according to a time schedule 9 6 3 Alarm states 10 6 4 Standard operating modes 11 6 5...

Page 3: ... modules of this design are intended for installation in Fermax Cityline and Fermax Skyline door entry panels The module is supplied in MREM 79E versions as a PCB 1 Commercial designation of available versions is described in table 1 3 Technical parameters 3 1 Product version Product version Product designation Catalogue number Module features 2 TF EM HID MREM 79E TF 53479000 MREM 79E EM 53479001 ...

Page 4: ...g synchronization MASTER SLAVE modes Indicators 3x LED 1x PIEZO Tamper protection N A Communication interface RS 485 Alternative data input output WIEGAND configurable Table 2 Technical features 3 3 Special accessories Accessories WIO 22 51901200 Remote control module 2x relay Table 3 Special accessories 3 4 Using WIO 22 module for remote output control The WIO 22 remote control WIEGAND relay modu...

Page 5: ...tor for plugging in the C1 cable 8 wires cable C2 Connector for plugging in the C2 cable 3 wires cable C3 Connector for plugging in the C3 cable 7 wires cable J0 Configuration jumper for RS 485 line termination D1 Red green LED operating mode and card reading indication D2 Yellow LED programming mode and door lock release indication D3 Green LED door lock status indication Table 5 Connectors jumpe...

Page 6: ...tion jumpers 4 1 LED Indicators LED indicators D1 Red green Continuously lit red Online operating mode Flashing with 4 s period red Offline operating mode Fast switching red green Address setting mode RS 485 BUS testing mode Single flash green ID media reading D2 Yellow Continuously lit flashing Programming mode Short flashing with 1s per Indicating door lock release configurable D3 Green Indicati...

Page 7: ...nt generating electromagnetic fields Consequently a short distance between the reader modules themselves can cause reading malfunctions for correct operation it is necessary to keep a minimum distance of 50 cm Various metallic constructions may have a negative influence on this distance if there are any doubts it is recommended to make a practical test before final mounting Nearby metal surfaces m...

Page 8: ...0 s Acoustic signalization time Forced door 0 255 s 30 s Acoustic signalization time Door ajar 0 255 s 0 s Acoustic signalization time APB alarm 0 255 s 0 s Signalization time Card alarm 0 255 s 30 s Antipassback function setting See chapter 6 10 Disabled Automatic summer time adjustment YES NO YES Release lock with REX button when tamper alarm active YES NO YES Online authorization timeout 0 2550...

Page 9: ...tched and the beeper is activated when not disabled when the Door Open function is activated The beeper stays active until the door is opened or the preset door lock release time has elapsed see configuration table The door lock relay status remains unchanged until another Door Open function is activated In case the pulse function of the door lock relay is set the door lock relay status is switche...

Page 10: ...e relevant alarm states with setting of the signaling timer 0 occurs the alarm output is activated It can control any alarm device directly or it can be processed further After terminating all alarm conditions the alarm output is deactivated The alarm signaling is triggered by any alarm condition 6 3 1 Tamper alarm In case of tampering the module the status of input 2 or input 3 in proper configur...

Page 11: ...ying of the ID media codes length is required in combined systems with WIEGAND output readers with a fixed WIEGAND data format IDs more information in APS Reader user s guide available at http www techfass cz files m_aps_miniplus_reader_en pdf 6 5 2 HID Proximity ID media format When working with HID Proximity technology ID media the module operates with a code in a recognized 26 or 32 bit format ...

Page 12: ... 11 Signal function in WIEGAND operating mode Since the FW version 5 09 the reading synchronization of a couple of TECHFASS readers is implemented enabling to cancel the mutual disturbance of the modules The reader module offers the Wiegand data interface synchronization in MASTER mode 6 6 3 Wiegand input entry reader The module can be configured into a mode of controlling the door from both sides...

Page 13: ...serting cards into the reader module s memory Step 1 Step 2 Step 3 Read the programming card for inserting the reader goes into programming mode One by one read the cards which are to be granted access About 15 seconds after inserting the last card the reader module goes back into standard operating mode Pic 4 a Inserting cards 6 7 2 Deleting cards from the reader s memory For deleting the cards f...

Page 14: ...es into programming mode which is indicated by slow flashing of yellow LED Read the programming card for inserting 5 times in a row the reader will go into Deleting cards above or below mode indicated by fast flashing of yellow LED Read a card which is located in the module s memory right before or right after the card you wish to delete After this step the module quickly flashes with yellow LED S...

Page 15: ... adding and deleting cards should be stored in the table Following example shows correct usage of the programming cards and proper filing of the actions Inserting 5 new cards using the procedure from chapter 6 7 1 Read inserting programming card read cards 1 5 after 15 s the programming mode is exited create a table Pic 4 e Table after inserting 5 cards Card 3 gets lost Delete it using the card 4 ...

Page 16: ...deleting all cards using the procedure described in chapter 6 7 4 it is necessary to create a new filing table 6 8 ID expiration function This function is implemented since the FW version 5 0 It is possible to set an Expiration date for every ID stored in the module When the date occurs the ID becomes invalid expired The expiration evaluation is performed on every date change in the module s RTC a...

Page 17: ... relevant door is opened relevant input is disconnected 6 10 1 Time Antipassback The Time Antipassback is defined by the ABP timer initial value in minutes which is set to the ID after passing at the reader module If the users uses the ID at the address during the timer for the ID is running the Time APB alarm is raised Following parameters affect the Time APB function APB timer initial value defi...

Page 18: ...set at the second input and at the third input output port The logic of the function is individually configurable The function is active whenever one or both of the configured inputs are active The module behavior is as described below when the disabling function is active User with access driven by a time schedule cannot run the door open function User with access always granted is not affected b...

Page 19: ...ified access rights evaluation 8 Useful links Wiring diagrams http techfass cz diagrams aps mini plus en html Program equipment http techfass cz software and documentation en html VALID UNKNOWN ID FOUND ACCESS DRIVEN BY TIME SCHED ACCESS ALWAYS GRANTED HOLIDAY ACCESS GRANTED FOR HOLIDAY AND ACTUAL TIME ACCESS GRANTED FOR ACTUAL DAY TIME READING ID YES NO YES NO NO YES INVALID YES NO NO YES NO YES ...

Reviews: