Page 8
5 Setting parameters of the reader module
5.1 Configurable parameters
C
o
n
fi
g
u
ra
b
le
p
a
ra
me
te
rs
Parameter
Possible range
Default setting
Door lock release time
0
255 s
7 s
Door lock control setting
Direct / reverse
Direct
Door lock relay function setting
Standard / toggle / pulse
Standard
Permanent door lock release according to
a time schedule
Never / Schedule index
Never
Door lock status indication
YES / NO
NO
Acoustic signal of door lock release
YES / NO
YES
Door ajar time
0
255 s
20 s
First button configuration
Door contact / REX button
Door contact
Second input configuration
REX button / handle contact
/ external tamper / tamper /
disabling function
REX button
Third input / output port
Tamper / ext. buzzer signal
/ disabling function / reading
synchronization
Tamper
Acoustic signalization time - Tamper
0
255 s
30 s
Acoustic signalization time - Forced door
0
255 s
30 s
Acoustic signalization time – Door ajar
0
255 s
0 s
Acoustic signalization time – APB alarm
0
255 s
0 s
Signalization time – Card alarm
0
255 s
30 s
Antipassback function setting
See
chapter 6.10
Disabled
Automatic summer time adjustment
YES / NO
YES
Release lock with REX button when
tamper alarm active
YES / NO
YES
Online authorization timeout
0
25500 ms
800 ms
Standalone authorization after timeout
YES / NO
YES
Saving events in
the module’s
archive
Door opened
Enabled / Disabled
Enabled
Door closed
Enabled / Disabled
Enabled
Input 2 On
Enabled / Disabled
Enabled
Input 2 Off
Enabled / Disabled
Enabled
Strike released
Enabled / Disabled
Enabled
Strike closed
Enabled / Disabled
Enabled
Table 9: Configurable parameters
5.2 Reader module parameters setting
Detailed instructions for setting reader module parameters are described in the
APS
Reader
configuration
program
user’s
guide
available
at
the
address
http://www.techfass.cz/files/m_aps_miniplus_reader_en.pdf
.