Page 14
When the reader module operates in the entry reader operating mode, the I/O Port (
tab. 5
)
is used as an output for controlling the entry reader buzzer.
Since the
FW version 5.09
the reading synchronization of a
couple of TECHFASS readers
is
implemented, enabling to
cancel the mutual disturbance
of the modules. The reader module
offers the
Wiegand data interface
synchronization
in
SLAVE
mode.
The
WIEGAND input
and
WIEGAND output
operating modes are mutually exclusive.
6.7 Keypad function
The keypad function setting can be set to one of the following options:
•
Key code
– this option is used when the keypad is used for entering a code of reason
to exit.
•
PIN
– with this option selected the keypad is used for entering PIN codes, a correct PIN
is required for valid identification when this option is selected
If the “
Suppress PIN request according to a time schedule
” function is set, the PIN code
entering is not requested when the used time schedule is valid.
•
ID
– this option enables entering a code at the keypad which is used as a user’s read
ID medium; the time for locking up the keypad when an unknown ID is entered 5 times
in a row can be set there as well, the setting range is from 0 to 2550s with a 10s step.