10
Installing the temperature sensors
!
The distance between the sensor cables and sources of electromagnetic interfe-
rence must be at least 300 mm
The outlet sensor is either integrated in the measuring capsule or it must be installed
in the connector. The inlet sensor is installed in a special ball valve or immersion pocket
released for this type of sensor. – This applies vice versa for the inlet variant.
Î
1
1
Remove the pressure from the sensor installation location.
2
Unscrew the closing screw from the special ball valve.
3
Place the enclosed O-ring on the assembly pin. Only use one O-ring.
When replacing sensors, replace the old O-ring with a new one.
4
Using the assembly pin, turn the O-Ring into the bore hole of the closing screw with a
rotating movement.
5
Place the O-ring in its final position using the other end of the assembly pin.
6
Place the temperature sensor with the plastic screw in the bore hole of the closing
screw and tighten it
hand-tight
. Do not use any tools for this!
Functional check
1
Open the shut-off valves in the inlet and outlet.
2
Check the leak tightness of the union piece connector.
3
Press the push-button on the meter to switch on the display.
Final tasks
1
Apply seals to the union piece connectors and both temperature sensors.
2
Mark the connector visibly with the label enclosed, depending on the existing connec-
tor geometry.
Wall-mounted computer unit (optional)
The computer unit can be detached from the flow rate sensor and installed on the wall
using the wall bracket.
For this, press the side engaging points on the computer unit lightly and lift the computer
unit upwards from the flow rate sensor.
!
The cable length between the volume measuring section and the computer unit
is max. 47 cm and cannot be changed!
The display must be accessible at all times and readable without further aids!
Summary of Contents for Compact Ve
Page 56: ...56 x x Techem x x 2 x x TAVO TAVO x 4min 6K qi x x EN1434 14154...
Page 57: ...57 BG TE1 9 9 9 9 TE1 1 2 3 4 5 7 Techem 1 8 max 1 4 8 IST 9 9 9 2 1 4 7 8 TE1 5 O L 6 L...
Page 58: ...58 300mm 1 1 2 3 O O 4 5 6 1 2 3 1 2 max 47 cm...
Page 59: ...59 F 1 F 3 F 4 F 5 F 6 C 1 C1 2 1 F4 F1 F6 F3 F9 und F5 x x x x...
Page 62: ...62 x x Techem x x 2 x x TAVO TAVO x 4 6 qi x x 1434 14154...
Page 63: ...63 RU TE1 9 9 9 9 TE1 1 2 3 4 5 7 Techem 1 8 1 4 8 IST 9 9 9 2 1 4 7 8 TE1 5 L 6 L...
Page 64: ...64 300 1 1 2 3 4 5 6 1 2 3 1 2 47...
Page 65: ...65 F 1 F 3 F 4 F 5 F 6 C 1 C1 2 C1 F4 F1 F6 F3 F9 F5 x x x x...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 109: ......