background image

INSTALLATION

AC POWER LINKING

•   Attention! The installation must be carried out by qualified service personnel only. 
•   Improper installation can result in serious injuries and /or damage to property. 
•   Overhead rigging requires extensive experience! 
•   Working load limits should be respected, certified installation materials should be 

used, and the installed device should be inspected regularly for safety. 

•   Make sure the area below the installation place is free from unwanted persons during 

rigging, de-rigging and servicing. 

•   Locate the fixture in a well ventilated spot, far away from any flammable materials and/ 

or liquids. 

•   The fixture must be fixed at least 50cm from surrounding walls. 
•   The device should be installed out of reach of people and outside areas where 

persons may walk by or be seated. 

•   The device should be well fixed; a free swinging mounting is dangerous and should 

not be considered! 

•   Do not cover any ventilation opening as this may result in overheating 
•   Before first time use it must be inspected by professional staff to ensure it is safe. 
•   A safety inspection should be performed regularly every year. 
•   Never expose the lens to direct sunlight, even for a short period. This may damage the 

light effect or even cause a fire!

Connection between laser lights and DMX must use the shield cable of diameter greater 
than 0.5mm. Please use the attached 3 pin XLR plug/socket to connect the DMX output/ 
input interface. The connection between socket and cable is shown below (note the plug/ 
socket’s 3 pin number and position).

 Note, XLR plug/socket’s 3 pin cannot be touched by inner hull, connection between 
pins is not allowed. Except above connection, XLR plug/socket cannot be connected 
with XLR control line. Device receives international standard DMX512(1990) control 
signal. 

•   When using standard DMX512 control signal, the last device’s output interface must 

be connected to a DMX plug. This plug is putting a 120-ohm resistance between 
“canon” plug’s 2 pin and 3 pin. Shown in below diagram. Sticking this plug into the last 
device’s signal output interface will avoid the interference during the process of signal 
transmission.

DMX-Output

XLR Mounting-Sockets (Rear View)

Please use the power cable supplied, note that power voltage and frequency are the 
same as the marked voltage and frequency of device when connecting power. Every 
device’s power should be connected separately, so that device can be controlled 
individually.

The power cord specification table:

Cable (EU)

Cable (EU)

Pin

International

Brown

Black

Live

L

Light Blue

White

Neutral

N

Yellow/Green

Green

Earth

 

- 3 -

installation

 

       

 

Attention

The

 

installation

 

must

 

be

 

carried

 

out

 

by

 

qualified

 

service

 

personal

 

only.

 

Improper

 

installation

 

can

 

result

 

in

 

serious

 

injuries

 

and

 

/or

 

damage

 

to

 

property

 .

Overhead

 

rigging

 

required

 

extensive

 

experience!

 

Working

 

load 

limits

 

should

 

be

 

respected,

 

Certified

 

installation

 

materials

 

should

 

be

 

used,

 

the

 

installed

 

device should be inspected 

regularly for safety. 

            Make

 

sure

 

the

 

area

 

below

 

the

 

installation

 

place

 

is

 

free

 

from

 

unwanted

 

persons

 

during

 

rigging,

 

de-rigging

 

and 

servicing. 

            Locate

 

the

 

fixture

 

in

 

a

 

well

 

ventilated

 

spot,

 

far

 

away

 

from

 

any

 

flammable

 

materials

 

and/or

 

liquids.

 

The

 

fixture must 

be fixed at least 50cm from surrounding walls. 

            The

 

device

 

should

 

be

 

installed

 

out

 

of

 

reach

 

of

 

people

 

and

 

outside

 

areas

 

where

 

persons

 

may

 

walk

 

by

 

or

 

be

 

seated. 

            The device should be well fixed; a free swinging mounting is dangerous and may not be considered! 
            Do not cover any ventilation opening as this may result in overheating 

            Before the first time use, it must be inspected by professional staff to make sure safety,

 

, inspection regularly

 

every 

year. 
Never

 

expose

 

the

 

lens

 to 

direct

 

sunlight,

 

even

 

for

 

a

 

short

 

period,

 

This

 

may

 

damage

 

the

 

light effect

 

or

 

even cause fire! 

 

 
     

 

 
 
 
 
 
 
 
 
 
 
 

  AC power linking 

 
       

  Please use the attached power, note that power voltage and frequency 

          are the same as the marked voltage and frequency of device when 
          connecting power. Every device’ s power should be connected separately, 
          so that device can be controlled individually. 
             

 
The power cord specification table  
 

Cable(EU) 

Cable(US) 

Pin 

International 

Brown 

Black 

Live 

Liht blue 

White 

Neutral 

Yellow/Green 

Green 

Earth 

 

Summary of Contents for Rave SL-3410

Page 1: ...User Manual Dual Laser LED Light Show SL 3410 ...

Page 2: ...tiveness is impaired for example by cracks or deep scratches Change the lamp if it is damaged or thermally deformed After opening carefully unpack the carton and check contents to ensure that all parts are in good condition Contact the supplier or store of purchase immediately and retain packaging for inspection if any parts are damaged Follow this user manual to operate this unit making sure you ...

Page 3: ...vice is being transported According to EN 60825 1 2007 this product belongs to class 3B Direct eye contact may cause injury This product is for laser shows only The class 3B laser light should be operated by a professional operator only This is a show laser emitting radiation with a wavelength spectrum between 400 and 700nm and producing lighting effects for shows International laser safety regula...

Page 4: ... and frequency are the same as the marked voltage and frequency of device when connecting power Every device s power should be connected separately so that device can be controlled individually The power cord specification table Cable EU Cable EU Pin International Brown Black Live L Light Blue White Neutral N Yellow Green Green Earth 3 he installation must be carried out by qualified service perso...

Page 5: ...ndard DMX512 control signal the last device s output interface must be connected to a DMX plug This plug is putting a 120 ohm resistance between canon plug s 2 pin and 3 pin Showing as below pic Sticking this plug into the last device s signal output interface it will avoid the interference during the process of signal transmission MX must use the shied cable of diameter more than 0 5mm Please use...

Page 6: ...tive 15 Safety key laser switch 16 interlock An external remote laser switch 17 Insurance rings Connecting wire rope to prevent illegal operation and fall 18 Power input Power input socket built in protective tube and spare tube 19 Fuse To prevent the current over load No Name Function 1 Hanging Basket Laser show do not look directly into the hole 2 LED 5 Colour Output RGBAWx3W 3 Laser Aperture La...

Page 7: ... 8 W Aut 4 RGBWA Aut 5 Laser Aut 6 8 W UP DOWN to choose display speed S 1 is fastest S100 is slowest S 0 is defualt confirm FUNC UP DOWN ENTER ENTER DOWN Menu operating instruction Once after every power on laser the VERSION and MANUFACTURE INFORMATION will be shown in LCD monitor of rear panel When laser is powered on LCD monitor on rear panel shows the current operating standalone mode or DMX a...

Page 8: ...N to change operating mode parameter or DMX address into speed choice Auto Aut0 Laser RGBAW 8 W Aut 1 Laser RGBWA Aut 2 Laser 8 W Aut 3 RGBWA 8 W Aut 4 RGBWA Aut 5 Laser Aut 6 8 W UP DOWN to choose display speed S 1 is fastest S100 is slowest S 0 is defualt confirm Sound Sou0 Laser RGBAW 8 W Sou 1 Laser RGBWA Sou 2 Laser 8 W Sou 3 RGBWA 8 W Sou 4 RGBWA Sou 5 Laser Sou 6 8 W Confirm choice adjust s...

Page 9: ...OU0 130 144 SOU1 145 159 SOU2 160 174 SOU3 175 189 SOU4 190 204 SOU5 205 220 SOU6 221 255 DMX Mode DMX INSTRUCTIONS Slave Its work will follow the procedure in host device by DMX signal LED letter strobes means DMX signal or SLAVE signal is not connected correctly please check cable control panel and other equipment DMX D001 to D505 ...

Page 10: ...Amber 24 70 74 Amber Red 14 75 79 Red Blue 80 84 Blue White 85 89 Red Green Blue 123 90 94 Red Green Amber 124 95 99 Red Green White 125 100 104 Red Amber Blue 125 105 109 Red White Blue 135 110 114 Red Amber White 114 115 119 Amber Green Blue 234 120 124 Blue Green White 235 125 129 Amber Green White 245 130 134 Amber White Blue 345 135 139 Red Green Blue Amber 1234 140 144 Red White Blue Amber 1...

Page 11: ...w Fast Max 30Hz 255 Sound activated strobe mode CH5 8pcs White LED Control 0 9 Black Out 10 19 Picture1 Slow Fast 20 29 Picture2 Slow Fast 30 39 Picture3 Slow Fast 40 49 Picture4 Slow Fast 50 59 Picture5 Slow Fast 60 69 Picture6 Slow Fast 70 79 Picture7 Slow Fast 80 89 Picture8 Slow Fast 90 99 Picture9 Slow Fast 100 109 Picture10 Slow Fast 110 255 ON CH6 Laser 0 9 Black Out 10 49 Red On 50 89 Gree...

Page 12: ...152 H 203 mm Weight 4 2kg Power Input Range 100 240V 50 60Hz Rate 66W Fuse 2A Light Source Type Class 3B Laser Diodes LED CHIP Power Quantity Colour 1 Red 1 Green Laser Power Rate 100mW 50mW Wave Length 650mm 532mm Quantity Colour 1 Red 1 Green 1 Blue 1 Orange 1 White 2 Red 2 Green 2 Blue 2 Yellow LED Power Rate 3W 3W 3W 3W 3W 2W 2W 2W 2W Wave Length 620mm 520mm 460mm 600mm 6500K Distributed by Te...

Reviews: