TECH ST-2640 User Manual Download Page 8

TECH 

 

 

Then, the user should release the button when the LED goes out and should press it again 
to adjust the second digit of the requested number – the LED flashes quickly two times. 
Holding the button, the user should wait until the LED flashes the requested number of 
times. After the button is released, the LED flashes two times – this means that the new 

channel has been programmed.  
 
NOTE:  
If the user adjusts a single-digit channel (channels 0÷9), 0 should be adjusted as the first 
digit.  
When the LED goes on for approx. 2 seconds, this signals errors in the channel change 
process. In this case, the channel is not changed. 

 
 

b.

 

Each room sensor should be assigned to a given zone. By default, each sensor is assigned 
to zone 1.  

 

 

CAUTION 

Only one room sensor may be assigned to one zone. 

 
 
Assigning the EU-261r room sensor to the selected zone: 
In order to assign the room sensor to the selected zone, the user should press and hold 
the channel change button on the  EU-261r controller. The LED will begin flashing  – the 
number of flashes indicates the number of the zone. The user should release the channel 
change button when the flashing LED reaches the number of the selected zone. 

c.

 

A separate set temperature and a weekly schedule may be adjusted for each room sensor 
assigned  to  a  given  zone.  These  settings  may  be  changed  both  in  the  controller's  menu 
(Main menu / Sensors) as well as at oeg.emodule.eu (using the ST-5072 module).  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Channel 

change 

button 

LED 

Summary of Contents for ST-2640

Page 1: ...EU 2640 user s manual 1 User s manual ST 2640...

Page 2: ...and description of the main screen 9 VII Controller s functions Main menu 10 VII a Chart of the controller s menu 10 VII b Manual operation 11 VII c Channel 11 VII d External sensor 11 VII e Sensors 1...

Page 3: ...ng cables installing the device etc The device should be installed by a qualified electrician Before starting the controller the user shoud measure earthing resistance of the electric motors as well a...

Page 4: ...n the building Due to its expanded software the regulator may perform a number of functions the operation of temperature regulator actuators 230V one output 230V for the pump dry contact the possibili...

Page 5: ...m touching live connections Before working on the regulator switch off the power supply and prevent it from being switched on again The EU 2640 regulator may be installed as a free standing device or...

Page 6: ...TECH 6...

Page 7: ...er should activate it in the controller s menu Main menu Fitter s menu Internet module Activated 4 If the set includes an external sensor the user should activate its operation by selecting Main menu...

Page 8: ...Each room sensor should be assigned to a given zone By default each sensor is assigned to zone 1 CAUTION Only one room sensor may be assigned to one zone Assigning the EU 261r room sensor to the selec...

Page 9: ...cating with the EU 2640 strip by means of a radio signal they require a registration process VI b View and description of the main screen The device is controlled by means of buttons located next to t...

Page 10: ...t Valve 1 8 Channel Czhannel 35 Range 0 55 External sensor Deactivated Wireless Sensors Zone 1 8 Deactivated Activated Set Weekly control Calibration Hysteresis Registration Pump Delay Language select...

Page 11: ...or may be connected to the controller that allows the user to monitor the current temperature on the main screen After the external sensor is mounted the user should mark the option Wireless in the co...

Page 12: ...s adjusted as 00 00 this temperature will be valid for an indefinite period of time The value of the set temperature along with the time until its end is displayed on the main screen on a current basi...

Page 13: ...perature in the room drops to 21 C Registration When wireless temperature regulator actuators are used it is necessary to register a given actuator in the zone The user may select 8 zones Valve 1 8 no...

Page 14: ...h an Internet module which makes it possible to monitor and change certain parameters via the Internet Control of this type is possible only after connecting an additional ST 5072 control module to th...

Page 15: ...larm from the strip level The user marks the zone where the alarm is present exclamation mark instead of the strip number The user presses the EXIT button the screen will show two options to select fr...

Page 16: ...y while holding the EXIT button The user should hold the EXIT button until a single acoustic signal is heard this means that the new software is being uploaded After the task is completed the controll...

Page 17: ...ns of the Low Voltage Directive LVD 2006 95 EC an act of April 13 2007 concerning Electromagnetic Compatibility Journal of Laws 07 82 556 implementing provisions of EMC directive 2004 108 EC the regul...

Page 18: ...TECH 18...

Page 19: ...EU 2640 user s manual 19...

Page 20: ...TECH 20...

Reviews: