VII.f) Pump 

The EU-2640 regulator controls the operation of the pump – it activates the pump after the delay 
time when any zone is insufficiently heated. When all zones are reheated (the set temperature is 
reached), the controller deactivates the pump.  
The function Delay allows the user to adjust the delay time for the pump's deactivation after the 
temperature drops in any zone below the set value. The delay in pump activation is used for the 
valve's actuator to open.  
 

VII.g) Language selection 

This function allows the user to change the controller's language version. 

 

 

VII.h) Display contrast 

This function allows the user to adjust the display's contrast to their individual needs. 

 

VII.i) Fitter's menu 

The Fitter's Menu is intended to be operated by people with appropriate qualifications and is used 
primarily to adjust the controller's additional functions. 
 

 

External sensor correction

 

The external sensor is calibrated during the installation or after a longer period of the regulator's 
operation if the displayed external temperature differs from the actual temperature. Adjustment 
range: -10 to +10°C with accuracy to 0.1°C. 
 

 

Internet module

 

The EU-2640 regulator may operate with an Internet module which makes it possible to monitor 
and  change  certain  parameters  via  the  Internet.  Control  of  this  type  is  possible  only  after 
connecting an additional ST-5072 control module to the controller. 
 
The Internet module may be connected with the  EU-2640 controller via an RS cable. After the 
module  is  connected,  the  user  selects  the  option  Registration.  The  code  generated  by  the 
controller is entered on the website – a detailed description may be found in the Internet module's 
user's manual.  
 
The Internet module is a device allowing the user to remotely control the regulator's operation 
via the Internet. The user controls the condition of all valves on their personal computer at home. 
 
After  the  user  activates  the  Internet  module  and  selects  the  DHCP  option,  the  controller  will 
automatically download the following parameters from the local network: IP address, IP mask, 
Gateway address and DNS address. In the case of any problems with downloading the network 
parameters, it is possible to adjust these parameters manually. The method of obtaining the local 
network parameters is described in the manual for the Internet module. 
 

 

Timer

 

This function allows the user to adjust the current time and day of the week.  
 

VII.j) Information on software 

After this option is activated, the display will show the boiler manufacturer's logo along with the 
controller's software version. 
 
 
 
 
 
 
 
 
 

Summary of Contents for ST-2640

Page 1: ...EU 2640 user s manual 1 User s manual ST 2640...

Page 2: ...and description of the main screen 9 VII Controller s functions Main menu 10 VII a Chart of the controller s menu 10 VII b Manual operation 11 VII c Channel 11 VII d External sensor 11 VII e Sensors 1...

Page 3: ...ng cables installing the device etc The device should be installed by a qualified electrician Before starting the controller the user shoud measure earthing resistance of the electric motors as well a...

Page 4: ...n the building Due to its expanded software the regulator may perform a number of functions the operation of temperature regulator actuators 230V one output 230V for the pump dry contact the possibili...

Page 5: ...m touching live connections Before working on the regulator switch off the power supply and prevent it from being switched on again The EU 2640 regulator may be installed as a free standing device or...

Page 6: ...TECH 6...

Page 7: ...er should activate it in the controller s menu Main menu Fitter s menu Internet module Activated 4 If the set includes an external sensor the user should activate its operation by selecting Main menu...

Page 8: ...Each room sensor should be assigned to a given zone By default each sensor is assigned to zone 1 CAUTION Only one room sensor may be assigned to one zone Assigning the EU 261r room sensor to the selec...

Page 9: ...cating with the EU 2640 strip by means of a radio signal they require a registration process VI b View and description of the main screen The device is controlled by means of buttons located next to t...

Page 10: ...t Valve 1 8 Channel Czhannel 35 Range 0 55 External sensor Deactivated Wireless Sensors Zone 1 8 Deactivated Activated Set Weekly control Calibration Hysteresis Registration Pump Delay Language select...

Page 11: ...or may be connected to the controller that allows the user to monitor the current temperature on the main screen After the external sensor is mounted the user should mark the option Wireless in the co...

Page 12: ...s adjusted as 00 00 this temperature will be valid for an indefinite period of time The value of the set temperature along with the time until its end is displayed on the main screen on a current basi...

Page 13: ...perature in the room drops to 21 C Registration When wireless temperature regulator actuators are used it is necessary to register a given actuator in the zone The user may select 8 zones Valve 1 8 no...

Page 14: ...h an Internet module which makes it possible to monitor and change certain parameters via the Internet Control of this type is possible only after connecting an additional ST 5072 control module to th...

Page 15: ...larm from the strip level The user marks the zone where the alarm is present exclamation mark instead of the strip number The user presses the EXIT button the screen will show two options to select fr...

Page 16: ...y while holding the EXIT button The user should hold the EXIT button until a single acoustic signal is heard this means that the new software is being uploaded After the task is completed the controll...

Page 17: ...ns of the Low Voltage Directive LVD 2006 95 EC an act of April 13 2007 concerning Electromagnetic Compatibility Journal of Laws 07 82 556 implementing provisions of EMC directive 2004 108 EC the regul...

Page 18: ...TECH 18...

Page 19: ...EU 2640 user s manual 19...

Page 20: ...TECH 20...

Reviews: