TECH ST-2640 User Manual Download Page 7

EU-2640 user’s manual 

 

 

IV.

 

Radio communication 

The EU-2640 controller may communicate with certain devices by means of radio communication: 
 

 

 

Function

 

Configuration

 

 

EU-261r  room 
temperature 
sensor

 

It  makes  it  possible  to 
transmit  information  on 
the  current  temperature 
in the room 

-  the  current  communication 
channel needs to be the same 
as in the EU-2640 regulator 
-  a  given  sensor  should  be 
assigned to the selected zone, 
the  desired  zone  should  be 
adjusted in the sensor.  

 

EU-291 
external 
temperature 
sensor 

It makes it possible to 
monitor the external 
temperature. 

- the current communication 
channel needs to be the same 
as in the EU-2640 regulator 

 

STT-868 
wireless 
temperature 
regulator 
actuator 

It makes it possible to 
maintain the set 
temperature.  

- registration necessary in the 
EU-2640 controller 

 
 
 
 

V.

 

First start-up 

In order for the controller to operate correctly, the user should proceed according to the following 
steps during the first start-up: 

1.

 

Connect the cables. 

2.

 

Switch on the controller's power supply.  

3.

 

If the set includes the EU-507 Internet module, the user should activate it in the controller's 
menu: 

Main menu / Fitter's menu / Internet module / Activated

4.

 

If the set includes  an  external sensor, the user  should activate its operation by selecting: 
Main menu / External sensor / Wireless. 

5.

 

Configuration of temperature sensors transmitting information on the current temperature in 
a given zone.  

a.

 

The user should determine whether the current communication channel in the temperature 
sensors  is  the  same  as  in  the  EU-2640  regulator.  The  factory  setting  in  both  devices  is 
channel  35,  so  if  the  user  has  a  new  set  there  is  no  need  to  adjust  the  communication 
channel. The communication channel should be changed to another only when the operation 
of the devices is disturbed by other radio signals.  

 

Changing the channel in the EU-261r room sensor:  
It  may  be  necessary  to  change  the  communication  channel  in  the  event  of  radio 
interference. In order to change the channel to a different one, the user should press the 
channel change button 

twice

 - holding it the second time. When the LED on the sensor 

flashes,  this  means  that  the  channel  change  process  has  started.  Holding  the  channel 
change button all the time, the user should wait until the LED flashes as many times as 
the value of the first digit of the requested channel number.  
 
 
 
 

Summary of Contents for ST-2640

Page 1: ...EU 2640 user s manual 1 User s manual ST 2640...

Page 2: ...and description of the main screen 9 VII Controller s functions Main menu 10 VII a Chart of the controller s menu 10 VII b Manual operation 11 VII c Channel 11 VII d External sensor 11 VII e Sensors 1...

Page 3: ...ng cables installing the device etc The device should be installed by a qualified electrician Before starting the controller the user shoud measure earthing resistance of the electric motors as well a...

Page 4: ...n the building Due to its expanded software the regulator may perform a number of functions the operation of temperature regulator actuators 230V one output 230V for the pump dry contact the possibili...

Page 5: ...m touching live connections Before working on the regulator switch off the power supply and prevent it from being switched on again The EU 2640 regulator may be installed as a free standing device or...

Page 6: ...TECH 6...

Page 7: ...er should activate it in the controller s menu Main menu Fitter s menu Internet module Activated 4 If the set includes an external sensor the user should activate its operation by selecting Main menu...

Page 8: ...Each room sensor should be assigned to a given zone By default each sensor is assigned to zone 1 CAUTION Only one room sensor may be assigned to one zone Assigning the EU 261r room sensor to the selec...

Page 9: ...cating with the EU 2640 strip by means of a radio signal they require a registration process VI b View and description of the main screen The device is controlled by means of buttons located next to t...

Page 10: ...t Valve 1 8 Channel Czhannel 35 Range 0 55 External sensor Deactivated Wireless Sensors Zone 1 8 Deactivated Activated Set Weekly control Calibration Hysteresis Registration Pump Delay Language select...

Page 11: ...or may be connected to the controller that allows the user to monitor the current temperature on the main screen After the external sensor is mounted the user should mark the option Wireless in the co...

Page 12: ...s adjusted as 00 00 this temperature will be valid for an indefinite period of time The value of the set temperature along with the time until its end is displayed on the main screen on a current basi...

Page 13: ...perature in the room drops to 21 C Registration When wireless temperature regulator actuators are used it is necessary to register a given actuator in the zone The user may select 8 zones Valve 1 8 no...

Page 14: ...h an Internet module which makes it possible to monitor and change certain parameters via the Internet Control of this type is possible only after connecting an additional ST 5072 control module to th...

Page 15: ...larm from the strip level The user marks the zone where the alarm is present exclamation mark instead of the strip number The user presses the EXIT button the screen will show two options to select fr...

Page 16: ...y while holding the EXIT button The user should hold the EXIT button until a single acoustic signal is heard this means that the new software is being uploaded After the task is completed the controll...

Page 17: ...ns of the Low Voltage Directive LVD 2006 95 EC an act of April 13 2007 concerning Electromagnetic Compatibility Journal of Laws 07 82 556 implementing provisions of EMC directive 2004 108 EC the regul...

Page 18: ...TECH 18...

Page 19: ...EU 2640 user s manual 19...

Page 20: ...TECH 20...

Reviews: