Tech Novitas FZC: P.O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
Tech Novitas Corp. LLC ,Wyoming, U.S.A, Tech Novitas ( Far East) Ltd, Hong Kong.
www. technovitas.com Email us at: [email protected]
14
permission of the advanced user.
password:66 for factory parameters, can set parameters of the
whole system
a
、
Keep clicking on
+
keys for 5 sec, enter password
b
、
Click
or
keys to set password, click
keys to enter
c
、
Click
or
keys to entry select parameters menu( S-P)
,
and
Permissions Settings menu
(
L-P
),
click
to confirm parameter
modification, click
to cancel parameter modification.
d
、
Clicking on
keys
,
return to last menu
3.2 Parameters Menu
Parameters
Type
Code
Default
class
units
scope
Default value
Main Menu
Room temperature
R
℃
Indoor temperature
R
b01
Outdoor temperature R
b02
Probe parameters setting Menu -/-
Indoor temperature
Probe B1
R/W
/01
F
0=Not present
1=present
1
Indoor temperature
Probe B2
R/W
/02
F
0=Not present
1=present
1
Probe B1 calibration
R/W
/13
F
-12.0~12.0
0.0
Probe B2 calibration
R/W
/14
F
-12.0~12.0
0.0