background image

EU-297  

 

11 

 

VI.

 

HOW TO USE THE CONTROLLER 

1.

 

PRINCIPLE OF OPERATION  

The EU-297v2 room regulator is designed to maintain the pre-set room temperature by sending a signal to the heating 
device or the main controller when the pre- set room temperature has been reached. After receiving such a signal, the 
heating device turns off. 

NOTE 

For the floor heating functions to be available, the floor sensor must be enabled in the controller menu. 

2.

 

OPERATION MODES 

The room regulator may operate in one of the following operation modes:  

 

Day/night mode – In this mode the pre-set temperature value depends on the current time of the day. The user 
may set different temperature values for the daytime and nighttime as well as define the exact time of entering 

day mode and night mode.  In order to activate this mode, press MENU button until one of the mode icons

 

appears on the main  screen.  The user  may define the pre-set  temperature and (after tapping on MENU 

again) the time of entering day and night mode. 

 

 

Manual mode      

 In this mode, the pre-set temperature is adjusted manually from the main screen view 

with the use of these buttons:  

 . Manual mode is activated after pressing MENU button. Once the manual 

mode  has  been  activated,  the  previous  operation  mode  enters  ‘sleep  mode’  until  the  next  pre-programmed 
temperature change. Manual mode may be deactivated by pressing EXIT button.  

VII.

 

DEVICE DESCRIPTION 

The user operates device using toutch buttons. 

 

 

 

 

 

 

 

Summary of Contents for EU-297 v2

Page 1: ...EU 297 v2...

Page 2: ...VII Device description 11 1 Main screen description 12 VIII Controller functions 13 1 Block diagram main menu 13 1 1 Clock 13 1 2 Pre set day temperature 13 1 3 Day from 14 1 4 Pre set night temperatu...

Page 3: ...ce etc The device should be installed by a qualified electrician The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disco...

Page 4: ...e pre set value The EU 297v2 controller functions Maintaining pre set room temperature Manual mode Day night mode Control of the floor sensor Possibility of pairing with the EU MW 3 module Controller...

Page 5: ...ver included in the controller set mounted near the heating device Hardware versions 1 EU 297 v2 RB EU 297 v2 RBN wireless version powered with two AAA 1 5V batteries 2 EU 297 Z v2 RZ EU 297 v2 RZN wi...

Page 6: ...two wire communication cable should be connected to the appropriate connectors on the receiver The EU 297v2 room regulator may be used as a wall mountable panel In order to mount it place the rear pa...

Page 7: ...ng device with a two core cable The cable connection of both devices is shown in the diagram below NOTE The regulator is powered with batteries it is recommended to check the batteries from time to ti...

Page 8: ...F THE REGULATOR POWER SUPPLY 230V The room regulator may be used as a wall mountable panel In order to mount it place the rear part of the controller in the mounting box on the wall insert the regulat...

Page 9: ...EU 297 9 The room regulator should be connected to the heating device with a two core cable The cable connection of both devices is shown in the diagram below heating device heating device...

Page 10: ...erature fails to reach the pre set value the heating device is switched on NOTE In case of no communication e g due to discharged battery the receiver automatically disables the heating device after 1...

Page 11: ...y The user may set different temperature values for the daytime and nighttime as well as define the exact time of entering day mode and night mode In order to activate this mode press MENU button unti...

Page 12: ...ton to enable manual mode or to set calibration Press the MENU button to move on to edit next parameters 1 MAIN SCREEN DESCRIPTION 1 Battery level battery version 2 Maximum minimum floor temperature t...

Page 13: ...AGRAM MAIN MENU 1 1 CLOCK In order to set the time press MENU button until the clock settings appear on the screen The settings concern the flashing parameter Use or to set the hour Next press MENU to...

Page 14: ...to define the exact time of entering the night mode To configure this parameter press MENU until a flashing icon appear on the screen Use or to set the time of night mode activation 1 6 HYSTERESIS Roo...

Page 15: ...es the tolerance for the maximum and minimum temperature The settings range is from 0 2 C to 5 C If the floor temperature exceeds the maximum temperature the underfloor heating will be disabled It wil...

Page 16: ...sensor differs from the actual temperature Calibration setting range is from 9 9 to 9 9 C with the accuracy of 0 1 C To calibrate the built in sensor press the MENU button until the temperature senso...

Page 17: ...y button on the panel or click the registration button Pressing the registration button again will allow pairing Once registration has been activated in EU MW 3 it is necessary to press the registrati...

Page 18: ...y 2xAAA 1 5V batteries Measurement error 0 5o C Operation frequency 868MHz EU 297Z v2 Temperature adjustment range 5o C 35o C Power supply 230V 10 50Hz Max power consumption 0 1W Measurement error 0 5...

Page 19: ...the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amend...

Page 20: ...TECH 20...

Reviews: