![Tech Controllers EU-297 v2 User Manual Download Page 10](http://html1.mh-extra.com/html/tech-controllers/eu-297-v2/eu-297-v2_user-manual_829348010.webp)
TECH
10
IV.
WIRELESS CONTROLLER RECEIVER
The EU-297v2 regulator communicates with the heating device (or the CH boiler controller) by means of a radio signal
sent to the receiver. Such a receiver is connected to the heating device (or the CH boiler controller) by means of a two-
core cable, and communicates with the room regulator using a radio signal.
The receiver has three control lights:
• red control light 1 – signalises data reception;
• red control light 2 – indicates receiver operation;
• red control light 3 – goes on when the room temperature fails to reach the pre-set value – the heating device is switched
on.
NOTE
In case of no communication (e.g. due to discharged battery), the receiver automatically disables the
heating device after 15 minutes.
V.
FIRST START-UP
In order for the EU-297v2 controller to work properly, it is necessary to follow these steps when starting the device for
the first time:
1.
Insert the batteries - in order to to do it, remove the front cover of the controller (battery version).
2.
Connect the controller to the heating device.
3.
If you want to use a room regulator to operate the floor heating system, connect an additional sensor to the floor
sensor connector.