background image

TECH 

 

II.

 

DEVICE DESCRIPTION 

The EU-293v3 room regulator is intended for controlling the heating or cooling device (e.g. gas, oil or electric boiler or the 
boiler controller). 

Its main task is to maintain the pre-set temperature in the flat by sending a signal to the heating/cooling device (contact 
opening) when the desired temperature is reached.   

Advanced software enables the regulator to fulfil a wide range of functions:  

 

maintaining the pre-set room temperature 

 

manual mode 

 

day/night program 

 

weekly control 

 

underfloor heating system control (optional; an additional temperature sensor is necessary) 

Controller equipment: 

 

touch buttons 

 

front panel made of 1mm glass 

 

built-in temperature sensor 

 

batteries (battery-powered version) 

The EU-293v3 room regulator offers two display versions:  

 

standard (the data is displayed in black against white background) 

 

negative (the data is displayed in white against black background) 

 

Two colour versions available 

WHITE

 

BLACK

 

 

 

 

Hardware versions: 

1.

 

EU-293  B  v3  –  wired  version,  powered  with  two  AAA  1,5V  batteries,  with  a  temporary backlight.  Colour 
versions: black or white.  
 

2.

 

EU-293  Z  v3  –  wired  version,  powered  with  230V,  with  a  temporary  backlight.  Colour  versions:  black  or 
white.  

Summary of Contents for EU-293 B v3

Page 1: ...EU 293 User manual 1 EU 293v3...

Page 2: ...s 14 4 1 Block diagram main menu 15 4 2 Day of the week 15 4 3 Clock settings 16 4 4 Day from 16 4 5 Night from 16 4 6 Button lock 16 4 7 Optimum start 16 4 8 Automatic manual mode 17 4 9 Weekly contr...

Page 3: ...es installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make sur...

Page 4: ...control underfloor heating system control optional an additional temperature sensor is necessary Controller equipment touch buttons front panel made of 1mm glass built in temperature sensor batteries...

Page 5: ...EU 293 User manual 5 III HOW TO INSTALL THE CONTROLLER NOTE The device should be installed by a qualified electrician 1 HOW TO INSTALL BATTERY POWERED REGULATOR...

Page 6: ...heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Optionally it is possible to connect an additional sensor to th...

Page 7: ...3v3 room regulator may be used as a wall mountable panel In order to mount it place the rear part of the controller in the mounting box on the wall insert the regulator and turn it slightly 2 HOW TO I...

Page 8: ...heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Optionally it is possible to connect an additional sensor to th...

Page 9: ...PLE OF OPERATION The EU 293v3 room regulator is designed to maintain the pre set room temperature by sending a signal to the heating cooling device contact opening when the pre set room temperature ha...

Page 10: ...ay night mode icon appears on the main screen Weekly control This mode enables the user to define the time when the pre set comfort temperature and the pre set economical temperature will apply The us...

Page 11: ...ht mode When Day night mode is active the user changes the pre set temperature by pressing one of the buttons which automatically activates manual mode The controller returns to Day night mode when da...

Page 12: ...the main screen view press this button to switch to manual mode and decrease the pre set temperature value In the controller menu use this button to change parameter settings enter the service code et...

Page 13: ...et room temperature 7 Time 8 Buttery level this icon is displayed only in the battery powered version 9 An icon informing about room cooling heating The animation differs depending on the selected ope...

Page 14: ...s 4 CONTROLLER FUNCTIONS The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited paramet...

Page 15: ...week Press or until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week C...

Page 16: ...user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appe...

Page 17: ...ed change resulting from the previous operation mode is introduced If the function is disabled OFF the manual mode remains active regardless of the pre programmed changes 4 9 WEEKLY CONTROL This funct...

Page 18: ...the user opens up the program editing screen Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters...

Page 19: ...15 21 comfort temperature 22 00 economical temperature NOTE When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is select...

Page 20: ...nal sensor differs from the actual temperature Calibration setting range is from 10 to 10 C with the accuracy of 0 1 C To calibrate the built in sensor press the MENU button until the temperature sens...

Page 21: ...e set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hysteresi...

Page 22: ...on to edit the next parameter or press EXIT to confirm and return to the main screen view DEF factory settings This function enables the user to restore factory settings In order to do it select Def...

Page 23: ...ing to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the r...

Page 24: ...TECH 24...