background image

TECH 

 

16 

4.3.

 

CLOCK SETTINGS 

In  order  to  set  current  time,  press  MENU  until  time  setting  panel  is 

displayed on the screen. By pressing 

 or  

 set the hour and minutes.  

Press MENU to confirm and move on to the next parameter or press EXIT 
to confirm and return to the main screen view. 

 

4.4.

 

DAY FROM... 

This function enables the user to define the exact time of entering the day mode. When Day/night mode is active, comfort 
temperature applies at daytime. To configure this parameter press MENU 

until Day from… setting appears on the screen. By pressing 

 or  

 set 

the hour and minute of day mode activation.   

Press MENU to confirm and move on to the next parameter or EXIT to 
confirm and return to the main screen view. 

 

4.5.

 

NIGHT FROM... 

This  function  enables  the  user  to  define  the  exact  time  of  entering  the 
night  mode.  When  Day/night  mode  is  active,  economical  temperature 
applies at nighttime.To configure this parameter press MENU until Night 

from… setting appears on the screen. By pressing 

 or  

 set the hour 

and minute of night mode activation.   

Press MENU to confirm and move on to the next parameter or press EXIT 
to confirm and return to the main screen view. 

4.6.

 

BUTTON LOCK 

In  order  to  activate  the  button  lock,  press  MENU  until  a  padlock  icon 

appears. Use one of the buttons 

 or  

 to select ON. In order to unlock 

the buttons, press and hold the buttons 

at the same time, select the 

button lock function and select OFF

 

 

4.7.

 

OPTIMUM START 

Optimum  start  is  an  intelligent  system  controlling  the  heating/cooling  process.  It  involves  constant  monitoring  of  the 
heating/cooling system efficiency and using the information to activate the heating/cooling  in advance in order to reach 
the pre-set temperatures.  

 

 

 

Summary of Contents for EU-293 B v3

Page 1: ...EU 293 User manual 1 EU 293v3...

Page 2: ...s 14 4 1 Block diagram main menu 15 4 2 Day of the week 15 4 3 Clock settings 16 4 4 Day from 16 4 5 Night from 16 4 6 Button lock 16 4 7 Optimum start 16 4 8 Automatic manual mode 17 4 9 Weekly contr...

Page 3: ...es installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make sur...

Page 4: ...control underfloor heating system control optional an additional temperature sensor is necessary Controller equipment touch buttons front panel made of 1mm glass built in temperature sensor batteries...

Page 5: ...EU 293 User manual 5 III HOW TO INSTALL THE CONTROLLER NOTE The device should be installed by a qualified electrician 1 HOW TO INSTALL BATTERY POWERED REGULATOR...

Page 6: ...heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Optionally it is possible to connect an additional sensor to th...

Page 7: ...3v3 room regulator may be used as a wall mountable panel In order to mount it place the rear part of the controller in the mounting box on the wall insert the regulator and turn it slightly 2 HOW TO I...

Page 8: ...heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Optionally it is possible to connect an additional sensor to th...

Page 9: ...PLE OF OPERATION The EU 293v3 room regulator is designed to maintain the pre set room temperature by sending a signal to the heating cooling device contact opening when the pre set room temperature ha...

Page 10: ...ay night mode icon appears on the main screen Weekly control This mode enables the user to define the time when the pre set comfort temperature and the pre set economical temperature will apply The us...

Page 11: ...ht mode When Day night mode is active the user changes the pre set temperature by pressing one of the buttons which automatically activates manual mode The controller returns to Day night mode when da...

Page 12: ...the main screen view press this button to switch to manual mode and decrease the pre set temperature value In the controller menu use this button to change parameter settings enter the service code et...

Page 13: ...et room temperature 7 Time 8 Buttery level this icon is displayed only in the battery powered version 9 An icon informing about room cooling heating The animation differs depending on the selected ope...

Page 14: ...s 4 CONTROLLER FUNCTIONS The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited paramet...

Page 15: ...week Press or until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week C...

Page 16: ...user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appe...

Page 17: ...ed change resulting from the previous operation mode is introduced If the function is disabled OFF the manual mode remains active regardless of the pre programmed changes 4 9 WEEKLY CONTROL This funct...

Page 18: ...the user opens up the program editing screen Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters...

Page 19: ...15 21 comfort temperature 22 00 economical temperature NOTE When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is select...

Page 20: ...nal sensor differs from the actual temperature Calibration setting range is from 10 to 10 C with the accuracy of 0 1 C To calibrate the built in sensor press the MENU button until the temperature sens...

Page 21: ...e set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hysteresi...

Page 22: ...on to edit the next parameter or press EXIT to confirm and return to the main screen view DEF factory settings This function enables the user to restore factory settings In order to do it select Def...

Page 23: ...ing to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the r...

Page 24: ...TECH 24...

Reviews: