background image

LIMITED WARRANTY

In the event a defect in material or workmanship is discovered in any of TECA’s
products within one year after the date they are delivered to Buyer,

: (a)

TECA is notified of the defect in writing by certified mail within 14 days of the
date of discovery; (b) TECA may then either, at its sole discretion, inspect the
product at Buyer’s location, or require that the product be made available at
Buyer’s expense at TECA’s premises for TECA’s inspection within 14 days of
the date of notification; and (c ) the products are defective and the defects
result from faulty materials and/or workmanship and not in any way from
accident, misuse, misapplication, mishandling, modification, or alteration by the
Buyer or the shipper,

TECA shall, at its sole option, repair or exchange

defective products free of charge to Buyer, or credit to buyer the price of the
defective products. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARE
EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED
UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER
DAMAGES WHETHER SPECIAL, INDIRECT, INCIDENTAL,
CONSEQUENTIAL, LOST PROFITS, BUSINESS INTERRUPTION, OR LOSS
OF BUSINESS OR CUSTOMER RELATIONSHIPS.

In order to return merchandise for any reason ( repair, replacement, or credit) a
return authorization number must be issued by TECA. New merchandise may
not be returned for credit beyond 60 days from shipment. Charges for
incidental or other damages may also be made. All returned goods must be
sent freight prepaid. A restocking charge of 15% will apply. On special
equipment and custom modified equipment orders, additional incremental
cancellation charges may be made.

and if

then

RETURNED GOODS, RESTOCKING CHARGES

Summary of Contents for 0-2171-0-000

Page 1: ...tallation Only qualified technicians should install this equipment If you have any questions regarding your equipment please do not hesitate to call us at 773 342 4900 and we will be happy to assist you We are open from 8 00 am 4 30 pm Central Time Included in this packet you will find Installation Notes for Air Conditioners Product Literature and Specifications Assembly Drawing SK050532 Wiring Dr...

Page 2: ...ften the most difficult to protect from condensation in this orientation due to the fin orientation gravity and any susceptible components below If a drip pan is employed by the end user use caution to place the pan far enough away from the internal fan to minimize the restriction of air flow The pan should cover the fin ends as well as the fan area When there is a choice the vertical orientation ...

Page 3: ...240 8 0 5 0 EXT 40 65 10 60 Wick UL1995 CSA22 2 AHP 1501HC 0 2131 1 000 1000 1100 120 240 8 0 5 0 TC 3F 40 65 10 60 Wick UL1995 CSA22 2 AHP 1501HC 0 2151 1 000 1000 1100 120 240 8 0 5 0 EXT 40 65 10 60 Wick UL1995 CSA22 2 AHP 1501XE 0 2181 4 000 1000 1100 120 240 8 0 5 0 TC 6F 40 65 10 60 Wick UL1995 CSA22 2 AHP 1501XE 0 21F1 4 000 1000 1100 120 240 8 0 5 0 85 F 30 C 40 65 10 60 Wick UL1995 CSA22 ...

Page 4: ...y 136x 42 6 Cold Sink y 10x 38 4 y 10x 40 5 y 10x 42 6 AHP 1501 DIMENSIONS MOUNTING STYLE Thru Mount ENVIRONMENTS SERVED NEMA 12 IP 52 NEMA 4 IP 56 RATING TRADITIONAL 1000 BTU hr 0 F T 1300 BTU hr 20 F T RATING DIN 3168 300 Watts L35 L35 187 Watts L35 L50 See page 10 AHP 1501 Air Conditioner Air Cooled Air Flow Pattern catalog 2011 working on qxp 6 28 2011 2 00 PM Page 27 ...

Page 5: ...55 116 5 52 140 8 X 10 32 Mounting taps 4 X 6 32 Mounting taps optional 15 05 382 4 59 117 4 57 116 11 99 305 Input Power Cord Temperature adjustment Circuit Breakers Notes Dimensions Inches Millimeters Dimensions do not include hardware ...

Page 6: ......

Page 7: ...ilisé par des personnes enfants compris dont les capacités physiques sensorielles ou mentales ou le manque d expérience et de connaissances à moins qu ils aient été donnés de surveillance ou d instructions concernant l utilisation de l appareil par une personne responsable de leur sécurité Les enfants doivent être surveillés afin de s assurer qu ils ne jouent pas avec l appareil Achtung Wenn das N...

Page 8: ...rates the same technology as the TC 6F It contains a single setting each for both heating and cooling as referenced below TC 1C AND TC 1H POWER TEMPERATURE SWITCHES Models TC 1C and TC 1H power temperature controllers with their small tolerance and reset differential are the simplest and most cost effective way to control a cooling or heating device VAC or VDC without a need for a relay For circui...

Page 9: ...ree of charge to Buyer or credit to buyer the price of the defective products ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL INDIRECT INCIDENTAL CONSEQUE...

Reviews: