TECDrive TEC-3 User Guide Revision 1.20
24
www.tecmotors.co.uk/tecdrive
7
A
n
al
og and
Di
gi
ta
l I
n
p
u
t
M
acr
o
Co
n
fi
gu
ra
ti
o
n
s
P-15
DI1
DI2
DI3 / AI2
DI4 / AI1
Diagram
14
STOP
RUN
DI2
E-TRIP
OK
DI2
DI4
PR
11
0
0
P-20
1
0
P-21
0
1
P-22
1
1
P-23
15
STOP
RUN
P-23 REF
AI1
Fire Mode
Analog Input AI1
1
16
STOP
RUN
P-23 REF
P-21 REF
Fire Mode
FWD
REV
2
17
STOP
RUN
DI2
Fire Mode
DI2
DI4
PR
2
0
0
P-20
1
0
P-21
0
1
P-22
1
1
P-23
18
STOP
RUN
FWD
REV
Fire Mode
Analog Input AI1
1
7.4.
Macro Functions - Keypad Mode (P-12 = 1 or 2)
P-15
DI1
DI2
DI3 / AI2
DI4 / AI1
Diagram
0
1
0
1
0
1
0
1
0
STOP
ENABLE
-
INC SPD
-
DEC SPD
FWD
REV
8
˄
------------------ START -----------------
˄
1
STOP
ENABLE
PI Speed Reference
2
STOP
ENABLE
-
INC SPD
-
DEC SPD
KPD REF
P-20 REF
8
˄
------------------ START -----------------
˄
3
STOP
ENABLE
-
INC SPD
E-TRIP
OK
-
DEC SPD
9
˄
---------------------------------------- START -------------------------------
˄
4
STOP
ENABLE
-
INC SPD
KPD REF
AI1 REF
AI1
10
5
STOP
ENABLE
FWD
REV
KPD REF
AI1 REF
AI1
1
6
STOP
ENABLE
FWD
REV
E-TRIP
OK
KPD REF
P-20 REF
11
7
STOP
RUN FWD
STOP
RUN REV
E-TRIP
OK
KPD REF
P-20 REF
11
˄
-----------FAST STOP (P-24)--------------
˄
8
STOP
RUN FWD
STOP
RUN REV
KPD REF
AI1 REF
AI1
14
STOP
RUN
-
-
E-TRIP
OK
-
-
15
STOP
RUN
PR REF
KPD REF
Fire Mode
P-23
P-21
2
16
STOP
RUN
P-23 REF
KPD REF
Fire Mode
FWD
REV
2
17
STOP
RUN
KPD REF
P-23 REF
Fire Mode
FWD
REV
2
18
STOP
RUN
AI1 REF
KPD REF
Fire Mode
AI1
1
9,10,11,12, 13 = 0
7.5.
Macro Functions - Fieldbus Control Mode (P-12 = 3, 4, 7, 8 or 9)
P-15
DI1
DI2
DI3 / AI2
DI4 / AI1
Diagram
0
1
0
1
0
1
0
1
0
STOP
ENABLE
FB REF (Fieldbus Speed Reference, Modbus RTU / CAN / Master-Slave defined by P-12)
14
1
STOP
ENABLE
PI Speed Reference
15
3
STOP
ENABLE
FB REF
P-20 REF
E-TRIP
OK
Analog Input AI1
3
5
STOP
ENABLE
FB REF
PR REF
P-20
P-21
Analog Input AI1
1
˄
------START (P-12 = 3 or 4 Only)--------
˄
6
STOP
ENABLE
FB REF
AI1 REF
E-TRIP
OK
Analog Input AI1
3
˄
------START (P-12 = 3 or 4 Only)--------
˄
7
STOP
ENABLE
FB REF
KPD REF
E-TRIP
OK
Analog Input AI1
3
˄
------START (P-12 = 3 or 4 Only)--------
˄
14
STOP
ENABLE
-
-
E-TRIP
OK
Analog Input AI1
16
15
STOP
ENABLE
PR REF
FB REF
Fire Mode
P-23
P-21
2
16
STOP
ENABLE
P-23 REF
FB REF
Fire Mode
Analog Input AI1
1
17
STOP
ENABLE
FB REF
P-23 REF
Fire Mode
Analog Input AI1
1
18
STOP
ENABLE
AI1 REF
FB REF
Fire Mode
Analog Input AI1
1
2,4,8,9,10,11,12,13 = 0
7.6.
Macro Functions - User PI Control Mode (P-12 = 5 or 6)
P-15
DI1
DI2
DI3 / AI2
DI4 / AI1
Diagram
0
1
0
1
0
1
0
1
0
STOP
ENABLE
PI REF
P-20 REF
AI2
AI1
4
1
STOP
ENABLE
PI REF
AI1 REF
AI2 (PI FB)
AI1
4
3, 7
STOP
ENABLE
PI REF
P-20
E-TRIP
OK
AI1 (PI FB)
3
4
(NO)
START
(NC)
STOP
AI2 (PI FB)
AI1
12
5
(NO)
START
(NC)
STOP
PI REF
P-20 REF
AI1 (PI FB)
5
6
(NO)
START
(NC)
STOP
E-TRIP
OK
AI1 (PI FB)
8
STOP
RUN
FWD
REV
AI2 (PI FB)
AI1
4
14
STOP
RUN
-
-
E-TRIP
OK
AI1 (PI FB)
16
15
STOP
RUN
P-23 REF
PI REF
Fire Mode
AI1 (PI FB)
1
16
STOP
RUN
P-23 REF
P-21 REF
Fire Mode
AI1 (PI FB)
1
17
STOP
RUN
P-21 REF
P-23 REF
Fire Mode
AI1 (PI FB)
1
18
STOP
RUN
AI1 REF
PI REF
Fire Mode
AI1 (PI FB)
1
2,9,10,11,12,13 = 0