Appendix A: Build-in
Specifications
18
16
Revised 9/04
Clearance from rear of unit above
trim panel to combustible
construction.
9 1/2” minimum clearance for the
hood to open to non-combustible
construction.
Description of
Measurement
G2000
25 5/8” (65.1 cm)
27 1/8” (68.9 cm)
6 7/8” (17.5 cm)
6 7/8” (17.5 cm)
6 7/8” (17.5 cm)
35 5/8” (90.5 cm)
35 5/8” (90.5 cm)
35 5/8” (90.5 cm)
35 3/4” (90.8 cm)
27 1/8” (68.9 cm)
27 1/8” (68.9 cm)
45 7/8” (116.5 cm)
A
B
C
D*
G4000
Horizontal Depth
of Opening
Vertical Depth
of Opening
Vertical Height
of Counter
Horizontal Width
of Opening
G3000
*
suggested height dimension
16”
16”
12”
1”
4 1/2”
unobstructed
ventilation area
under front of
cooking unit.
D
B
A
C
Clearance from sides of unit
above trim panel to
combustible construction.
1 1/2” diameter hole
for gas line
Minimum clearance from sides and back of unit to combustible construction
below top of unit: 0” from sides and 0” from back.
Minimum clearance from sides and back of unit to vertical combustible
construction extending above top of unit: 16” from sides and 16” from back.
Do not use this gas appliance under overhead combustible construction.
Trim