Removing Your LP Gas Cylinder

Procedure:

1. Close the Cylinder Valve by turning the Handwheel

clockwise until it stops.

2.  Remove the Coupling Nut by turning it counter-

clockwise.

3.  Release the latch and remove the cylinder from the

grill.

Quick Disconnect Instructions

(See Figure 4.)

Procedure:

1.  To connect, push back Sleeve of Socket. (See Figure

A.)

2. Insert Plug (See Figure B.), release Sleeve.
3. Push Plug until Sleeve snaps forward locking Plug in

Socket (See Figure C.). (THIS AUTOMATICALLY
TURNS ON GAS.)

4. To disconnect, push sleeve back and pull out plug.

(THIS AUTOMATICALLY SHUTS OFF GAS.)

Permanent Installation

CAUTION: 

GAS PIPING TO YOUR GRILL MUST BE IN

ACCORDANCE WITH LOCAL CODES. IN THE ABSENCE
OF LOCAL CODES, USE THE NATIONAL FUEL GAS
CODE ANSI Z223.1/NFPA 54 (LATEST EDITION) OR
CAN/CGA B-149.1, NATURAL GAS AND PROPANE
INSTALLATION CODE.

CAUTION:

THE GAS SUPPLY MUST BE TURNED OFF AT

THE GRILL WHEN THIS APPLIANCE IS NOT IN USE.

When ordered for use with Natural gas, the Sterling G-
Series grill comes adjusted to operate with Natural gas.
Qualified personnel should install the gas line. A Shut-off
Valve at the grill is required. This Valve must be design
certified by CSA International.
The grill and Shut-off Valve must be disconnected from
the gas supply piping system during any pressure testing
of the system at test pressures in excess of 

1

/

2

PSIG (3.5

kPa).
The grill must be isolated from the gas supply piping
system by closing its individual manual Shut-off Valve
during any pressure testing of the system at test pressures
equal to or less than 

1

/

2

PSIG (3.5 kPa). 

Gas Leak Test

WARNING:

DO NOT USE OPEN FLAME TO PERFORM

LEAK TEST!

WARNING: 

DO NOT ATTEMPT TO USE THE GRILL

WHEN YOU SMELL GAS OR FAIL A GAS LEAK TEST.

Make sure there is no open flame near the grill during
the test. Test for leaks every time the gas is re-connected.

Procedure:

1.  Turn all Burner Output Knobs to OFF.
2.  Open the Gas Supply Valve slowly.  Apply soapy

water solution to all connections including factory
connections.

3.  Look for bubbles around the connections. If bubbles

can be seen, close the Gas Supply Valve and tighten
the connection where the bubbles are. Then, repeat
steps 1 and 2. Make sure you don’t over-tighten the
connections.

4.  Proceed with grill use.

Gas Connection 

continued

8

Revised 9/04

SLEEVE

REGULATOR

TO

TO

TO

REGULATOR

REGULATOR

SOCKET

SOCKET

SLEEVE

TO

TO

TO

GRILL

GRILL

GRILL

PLUG

PLUG

(FIGURE C.)

(FIGURE B.)

(FIGURE A.)

Figure 4. 

Quick Disconnect Fittings

Summary of Contents for Sterling

Page 1: ...hermal Engineering Corporation P O Box 868 Columbia South Carolina 29202 0868 2741 The Boulevard Columbia South Carolina 29209 Telephone 803 783 0750 Toll free 800 331 0097 Fax 803 783 0756 Toll free...

Page 2: ...INSERT PAGE HERE...

Page 3: ...IF YOU SMELL GAS 1 SHUT OFF GAS TO THE APPLIANCE 2 EXTINGUISH ANY OPEN FLAME 3 OPEN LID 4 IF ODOR CONTINUES IMMEDIATELY CALL YOUR GAS SUPPLIER OR YOUR FIRE DEPARTMENT FOR YOUR SAFETY 1 DO NOT STORE O...

Page 4: ...ge caused by failure to follow the instructions in your Owner s Manual or alteration of the grill structure or components or from operator abuse negligence or accident DISCLAIMER OF IMPLIED WARRANTIES...

Page 5: ...e of accessories that afford you a wide range of opportunities for new and interesting uses of your grill Some of them like our rotisserie are options familiar to everyone Others like our deep fryer a...

Page 6: ...ent masonry or other suitable patio fixture or for mounting onto a mobile cabinet base See Appendix A for complete build in specifications Figure 1 page 5 shows the minimum required clearance of a mob...

Page 7: ...are on with one hand The base can be locked in place using the Base Brake mechanism WHICH SHOULD BE ENGAGED AT ALL TIMES See BASE BRAKE section on page 11 for more information General Overview You wil...

Page 8: ...B LP GAS CYLINDERS CONSTRUCTED AND MARKED IN ACCORDANCE WITH THE SPECIFICATIONS FOR LP GAS CYLINDERS OF THE U S DEPARTMENT OF TRANSPORTATION D O T OR NATIONAL STANDARD OF CANADA CAN CGA B339 CYLINDERS...

Page 9: ...from Cylinder Valve Outlet and Nipple as necessary 5 Inspect the Coupling Nut Nipple and Cylinder Valve for any damage dirt or debris Remove dirt or debris Replace any damaged parts with TEC specifie...

Page 10: ...ed This Valve must be design certified by CSA International The grill and Shut off Valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressu...

Page 11: ...using the Handwheel See Figure 2 Page 7 For Natural gas open the gas valve in the main line 4 Depress and rotate the Burner Output Knob to HIGH See Figure 5 5 Slowly rotate Spark Igniter knob clockwis...

Page 12: ...ip Tray being careful to locate the match between the burners While watching the flame to ensure that the match remains lit turn the Burner Output Knob for the burner to be lit to HIGH 6 Repeat this p...

Page 13: ...sh this look down under the glass at the burner while turning the adjustment screw Base Brake Your Sterling G Series cabinet comes equipped with a Base Brake mechanism for use while the grill is stati...

Page 14: ...and smoke greatly enhance the flavor by char broiling the food Smoking Method The G Series grill can be used very effectively as a smoker Use dry wood pellets or wet woodchips small chips not chunks...

Page 15: ...6 min Pork Chops Medium 6 min per side Spare Ribs High fire 5 min 20 min per side Low to finish Turn often Lamb Chops High fire 5 min 15 min per side Medium to finish Fish 1 lb Medium Low 6 8 min per...

Page 16: ...es should be avoided because they may leave small hard to remove deposits on the glass Protection of Burners The burners of your grill are designed to provide a long life of satisfactory performance H...

Page 17: ...ny charred residue and wipe glass with a damp paper towel as described under Care of Radiant Glass Emitter With a cool surface apply a few dabs the size of a dime of an approved cleaner and work the c...

Page 18: ...ning Vertical Depth of Opening Vertical Height of Counter Horizontal Width of Opening G3000 suggested height dimension 16 16 12 1 4 1 2 unobstructed ventilation area under front of cooking unit D B A...

Page 19: ...e Burner Ignition Procedures on pages 9 and 10 After the burner ignites operate the grill for 3 to 5 minutes on HIGH with the hood OPEN 3 Turn the Burner Output Knob to LOW Position the spit rod in th...

Page 20: ...HEAT AND EXTINGUISH WITH A CLASS A B C D FIRE EXTINGUISHER OR COVER FRYER WITH STEAMER LID UNTIL COOLED DO NOT PUT WATER ON HOT OR FLAMING OIL 1 Remove the Cooking Grid over the burner that will be u...

Page 21: ...ter or other non flammable liquid wine etc Repeat this throughout the cooking process so that the liquid level is maintained 4 Place the Steamer Screen in the bottom of the Fryer Cover the Deep Fryer...

Page 22: ...CE ALWAYS LEAVE AT LEAST 25 OF THE SURFACE OPEN FOR VENTILATION Griddle Use 1 Remove the Cooking Grid of the desired burner 2 Place the Griddle over the burner 3 Follow the Burner Ignition Procedures...

Page 23: ...G COOKING SURFACE ALWAYS LEAVE AT LEAST 25 OF THE SURFACE OPEN FOR VENTILATION Wok Use 1 Remove the Cooking Grid of the desired burner 2 Place the Wok support over the burner 3 Place the Wok in the Wo...

Page 24: ...660 for Sterling G4000 Drip Tray RFM1677 for Sterling G4000 Warming Rack RFM1659 for Sterling G4000 Heat Shield REG102QD Regulator w hose LP gas REGLP Regulator LP gas build in applications REGNT Regu...

Page 25: ...See Fig 8 Pg 10 f Adjust or replace regulator as necessary g Contact TEC Authorized Dealer Replace ceramic burner head Burner output at LOW setting is too hot or too cool a Reduce or increase low hea...

Page 26: ...Notes...

Reviews: