Press the Programming button 10 times within 10 seconds after the 

authentication. The Immobilizer will generate a series of 3 audible 

signals.

3. 

Select the option from the menu by pressing the Programming 

button a required number of times (equal to the number of 

the option). The Immobilizer will acknowledge the option 

number by a series of audible signals.

4. 

Go  to  option  setting  by  pressing  and  holding the brake 

pedal. The Alarm will notify of the option status by a series 

of audible signals of a changing duration.

5. 

 To adjust  the  settings  press  the  Programming  Button the 

number of times matching the number of steps from the 

current status to the required one. For example, to go from 

option 3 (Engine locking) to option 13 (Number of presses per 

brake pedal) press the Programming button 10 times. The 

Immobilizer will acknowledge the selected function by audible 

signals. Please remember that from the last function the 

program will go to the first one. Release brake pedal to switch 

indication from status to a number of current menu option. 

Now you can move to programming the next function or exit 

the programming mode.

6.   Programming  algorithm  for  function  8  –  Doors,  hood and 

trunk.

 Set 

any  combination  of  doors,  hood  and  trunk, which upon 

opening will generate a signal at a programmable output. For 

the purposes of this description, doors, hood and trunk are 

referred to as doors.

 With 

the brake pedal pressed go to option 8. The Immobilizer 

will generate 2 successive series of 8 audible signals, and 

then will emit irregular audible signals. After hearing the latter 

release the brake pedal. The Immobilizer will continue to emit 

intermittent audible signals. Open those doors (it can be done 

in advance), which are to be indicated by this output. All other 

doors should remain closed. Press brake pedal again. The 

Immobilizer will inform of the status by series of 8 signals, and 

the doors will be assigned to this output. If you do not press 

the brake pedal and abort programming, the Immobilizer will 

save previous settings. Release the brake pedal, while the 

Immobilizer goes back to indication of the option number.

7.   Programming  algorithm for function 10 – Original buttons.

With the brake pedal pressed go to option 10. The Immobilizer 

will generate 2 successive series of 10 audible signals, and 

then will emit intermittent audible signals. With the brake

pedal still engaged, press the required button (see Integrator 

files). If the Immobilizer recognized the button, it will stop 

emitting intermittent signals and go back to indicating option 

status by series of 10 signals. Release the brake pedal. Now 

the Immobilizer will indicate the option number. If you release 

the brake pedal before assigning a button, the Immobilizer will 

exit this option, save previous option settings, and go back to 

indication of the option number.

8. 

 

Programming algorithm for function 15 – Gearbox status.

 With 

the brake pedal pressed go to option 15. The Immobilizer will 

generate 2 successive series of 15 audible signals, and then 

will emit intermittent audible signals. While still holding the 

brake pedal, switch the transmission to required position: P, 

N, D* or R (you can move the handle to the required position 

in advance). For Easytronic gearbox the following positions 

are available: R, N, D*. automatic transmission – P, R, N, D*; 

manual transmission – only R. Release and press the brake 

pedal again. The Immobilizer will stop emitting intermittent 

signals and go back to indicating option status by series of 15 

signals. Release the brake pedal, while the Immobilizer goes 

back to indicating menu option number. If you do not press the 

brake pedal and abort programming, the Immobilizer will save 

previous settings.

9. 

 Go  to configuring the next option by pressing the Programming 

button the number of times matching the number of steps 

from the current option to the required one. For example, to 

go from option 3 (Engine locking) to option 12 (Speed check) 

press the Programming button 9 times. Please note that when 

navigating the menu options, the first option follows the last 

one.

The  Immobilizer  will  exit  programming  mode  and  save all 

configuration settings in energy independent memory when ignition 

is turned off or within 60 seconds after last menu action if the brake 

pedal is released.

*

All handle positions for vehicle advancement (D, S, M, L, etc.).

Summary of Contents for PRIZRAK-510

Page 1: ...510 v7 520 v7 T ECH NIC A L M A NUA L For smart cars smart car holders Immobilizer heart of auto theft protection sistem...

Page 2: ...mmobilizer will follow its algorithms The driver s door was opened Upon entering the Guard mode AntiHiJack feature goes through a series of phases and in case if the Guard mode was not deactivated the...

Page 3: ...e Wait for the confirming trill Maintenance mode Maintenance is an operation mode when all hijack protection and service functions of the Alarm are temporarily disabled The Alarm will notify of activa...

Page 4: ...rolling on vehicles where CAN bus control is not available Please see Integrator files software product for information on vehicle specific connection features Pin No 6 Ground is connected to vehicle...

Page 5: ...the steering wheel and steering wheel column joysticks buttons cruise control central unit control etc sequentially one after another Those buttons which after being pushed receive a response audible...

Page 6: ...setting for PRIZRAK 520 1 4 1 1 maximum 2 high 3 low 4 minimum After the Immobilizer is installed adjusts the sensitivity 9 Hazard lights control algorithm 1 5 Set automatically but can be set manuall...

Page 7: ...ange is within 5 to 10 km h 17 Front parking sensors control Generation of a constant level signal if the engine is on and the speed of the vehicle is less than 15 km h 18 Rear parking sensors control...

Page 8: ...the brake pedal while the Immobilizer goes back to indication of the option number 7 Programming algorithm for function 10 Original buttons With the brake pedal pressed go to option 10 The Immobilizer...

Page 9: ...y moment by turning off the ignition A trill will sound If no actions were taken within 60 seconds and brake pedal was released the Immobilizer will exit programming mode If the vehicle has travelled...

Page 10: ...just the setting of option 3 by pressing the Programming button 2 times i e increase the option value by 2 increments 1 2 3 Immobilizer will acknowledge the selection by emitting a sequence of 3 audib...

Page 11: ...ing PRIZRAK receives the information about the vehicle moving via CAN bus If the central unit was removed the relay will lock the engine using accelerometer once the vehicle starts moving yellow white...

Page 12: ...l Manual PRIZRAK 510 520 v7 Use the picture to draw arrangement of alarm units This can help when trying to find specific units Keep this sketch out of the reach of third parties Immobilizer units arr...

Page 13: ...arranty certificate 1 Connection diagram 1 Packing 1 Parameter Value Power supply voltage V 9 15 Maximum current consumption in standby mode mA 5 Maximum current consumption in standby mode mA 1200 fo...

Page 14: ...14 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Page 15: ...15 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Page 16: ...Ltd The product is produced according to TU 4573 009 78025716 12 Certificate of conformityTS RU C RU OC13 B 01026 The product conforms to the requirements of the Technical reglament of Custom Union T...

Reviews: