background image

18

ENGLISH     

Transmit Channel during Active Channel Scan Function 

Selected Channel

Selected Channel or   Prior Channel

Prior Channel or

actual Channel

actual Channel

Function of the Monitor Key

Out of Function Stopping briefly     Stopping 

Stopping briefly 

CTCSS & DCS

CTCSS & DCS

Noise Squelch

in toggle mode

CTCSS & DCS

Transmit Time-Out-Timer

Duration [s]

6) Technical Data

Freenet Frequency Range
Channel

Frequency [ MHz ] Channel   Frequency [ MHz ]    Channel   Frequency [ MHz ]

1

149,0250

2

149,0375

3

149,0500

Channel spacing:

12.5 kHz

Radiated Tx output power: 

500 mW 

Modulation type:

8K5F3E

Deviation:

max. 2.5 kHz ( narrow )

RX sensitivity:

+ 0,28 µV ( narrow )

Audio output power:

0.56 W at 8 

at 10 % THD

Supply voltage:

6 – 8 V

Current consumption:

Tx: 490 mA

Professional radio communication:
Frequency range: 

150 MHz – 174 MHz

Frequency step size:

6.25 kHz; 5 kHz

Channel separation:

narrow: 12.5 kHz / wide: 25 kHz

Tx output power: 

max. 5 W 

Modulation type:

FM

Deviation:

narrow: 2.5 kHz / wide: 5 kHz

RX sensitivity:

narrow: +  0,28µV / wide:  0,75µV 

Audio output power:

0.56 W at 8 

at 10 % THD

Supply voltage:

6 – 8 V

Current consumption:

Tx ( Low ): 490 mA; Tx ( High ): 1.5 A

Tx and AF out 560 mW :

180 mA

Standby without power down

60 mA

Standby with power down : 

30 mA

Dimensions ( cabinet ):

W/H/D: 59 x 117 x 42 mm

Weight with batteries and antenna:

322 g

manual  04.02.2005 14:28 Uhr  Seite 18

Summary of Contents for PT-2208S

Page 1: ...TEAM PT 2208S electronic Bedienungsanleitung Manual Mode d emploi Freenet optional erweiterbares VHF Betriebsfunkger t...

Page 2: ...Channel Selector 16 step 1 15 S 4 Volume Control with ON OFF switch VOLUME OFF 5 PTT Key PTT 6 Monitor Key 7 Double Socket 2 5 3 5 mm SPK MIC 8 Loudspeaker 9 Accumulator Displays and Controls 1 Antenn...

Page 3: ...rophone 14 7 Charging of the Accumulator 14 8 Low Power Indicator 14 Scan Function of the TEAM PT 2208S 14 1 Start of Scan Function 15 2 End of Scan Function 15 3 Restart of the Scan Function 15 4 Tra...

Page 4: ...in that way on the unit s rear panel that the 4 slip planes of the unit grip into the correspond ing guiding slots of the accumulator and that the accumulator s charging contacts show into the directi...

Page 5: ...nd the indicator light 2 is dark the channel is free Press also the monitor key 6 There must be a noise if the channel is not occupied To transmit depress and hold the PTT key 5 During transmission th...

Page 6: ...ts up green again The charging current is reduced to a very little value now trickle charge just to compensate the self discharging current Now you can take out the transceiver with mounted accumulato...

Page 7: ...on is stepping through the scanning list the unit transmits on the first channel of the scanning list When the pressing of the PTT key occurs while the scan function is resting on a channel the unit t...

Page 8: ...the wanted message the muting device lets the radio message pass from that moment on In case of sending DCS coded messages the unit transmits immediately after the PTT key has been pressed down a cert...

Page 9: ...or adjustments must not be carried out since each modification or unauthorised intervention will immediately cancel all and any guarantee or repair claims they are also likely to result in non conform...

Page 10: ...r 500 mW Modulation type 8K5F3E Deviation max 2 5 kHz narrow RX sensitivity 0 28 V narrow Audio output power 0 56 W at 8 at 10 THD Supply voltage 6 8 V Current consumption Tx 490 mA Professional radio...

Page 11: ...6N D116N D223N D343N D465N D654N D031N D125N D226N D346N D466N D662N D032N D131N D243N D351N D503N D664N D043N D132N D244N D364N D506N D703N D047N D134N D245N D365N D516N D712N D051N D143N D251N D371N...

Page 12: ...ebsfunkger t in Deutschland F r den Vertrieb und Betrieb als Betriebsfunkger t in electronic Team Electronic GmbH Bolongarostrasse 88 65929 Frankfurt am Main Tel 069 30 09 50 0 Fax 069 31 43 82 eMail...