Peak Force (PF) and Work Index (WI) Sensitivity
Touch the Up and Down arrows to change the sensitivity settings of the Peak Force and Work Index. Press
Default to return the setting to the factory default.
Default sensitivity settings typically work good for terminals and wire combinations that meet the minimum
Head Room criteria of 35% or greater. If the CQM II Fails crimps that you determine to be Good crimps, then
you may want to adjust the sensitivity of the analysis method that is causing this problem. In this case, adjust
the sensitivity to be less sensitive by a few points, for example 3.0 to 3.5 (the higher the number the less
sensitive).
If the CQM II is not detecting the crimp failures that you expect it to detect, then you may want to adjust the
sensitivity of the various analysis methods to be more sensitive by a few points, for example from 3.0 to 2.5.
Touch the next Sensitivity arrow or the right arrow icon to move to the next task.