Special Conditions for Safe Use

 

i.

 

Since models AST4300 and AST43LP Pressure Transducers are not earthed and a charge-generating mechanism may be 
present when in contact with non-metallic charge generating materials, the device shall be grounded before use.

 

ii.

 

This product is manufactured from light metal and in rare cases, potential ignition sources or sparks may result due to 
impact or friction. User is recommended to use caution during installation, particularly if the equipment is utilized in Zone 2 
locations.

 

iii.

 

The product label indicates that the process temperature range is -40°C to +125°C. Taking this into account, the 
user/installer shall take the precautions to ensure the operating service temperature of the overall pressure transducer 
assembly is between -40°C to +92°C.

 

Process Connection Installation

 

For threaded installations, use the 7/8” hex above the thread of the process 

connection to install the process. Do not use the body / housing for installation.

 

Maximum working pressure for the lowest pressure sensors 0.34MPa (50 psi) 

and maximum working pressure for the highest pressure sensors 137.9MPa 

(20,000 PSI) -- SINGLE SEAL.

 

Outlines & Wiring 

 

AST4300 / AST43LP with Metal Conduit & Cable

 

 

 

 

 

 

 

 

 

 

Cable / Hookup 

Wire Connections

 

Conduit with Cable

 

Output Type

 

Green

 

Black

 

Red

 

White

 

3 Wire Voltage

 

Case

 

GND

 

+V

 

S

 

4-20mA (2 wire 

loop powered)

 

Case

 

-V

 

+V

 

N/C

 

Summary of Contents for AST4300

Page 1: ...60079 7 2014 A1 2017 CAN CSA C22 2 No 60079 0 11 ANSI ISA 60079 0 05 CAN CSA E60079 15 02 ANSI ISA 60079 15 12 ANSI ISA 12 12 01 2007 CSA C22 2 No 213 M1987 End of model features SS or Z Class I Division 2 Groups A B C D Ambient Temperature 40 to 80 C Code T4 28Vdc 0 025A Process Temperature 40 to 125 C Metal Conduit Only Sira 14ATEX4112X IECEx CSA 14 0061X Ex ec IIC T4 Gc Class I Zone 2 AEx nA II...

Page 2: ...y a Non hazardous live source in accordance with CAN CSA C22 2 No 61010 1 04 e g limited energy source or a Class 2 Source AVERTISSEMENT Risque d explosion Déconnecter l appareil uniquement après avoir coupé l alimentation électrique ou avoir vérifié qu il n est pas installé en zone dangereuse Cet équipement doit être alimenté par une source directe non dangereuse conformément aux normes CAN CSA C...

Page 3: ...ns iii The product label indicates that the process temperature range is 40 C to 125 C Taking this into account the user installer shall take the precautions to ensure the operating service temperature of the overall pressure transducer assembly is between 40 C to 92 C Process Connection Installation For threaded installations use the 7 8 hex above the thread of the process connection to install t...

Page 4: ...ivity and TE Connectivity logo are trademarks All other logos products and or company names referred to herein might be trademarks of their respective owners The information given herein including drawings illustrations and schematics which are intended for illustration purposes only is believed to be reliable However TE Connectivity makes no warranties as to its accuracy or completeness and discl...

Reviews: