background image

15

PFE Series, simple function

 This range of ‘front end’ converters can be used to  
create quick to market, low profile single output PSU 
directly power user loads, or combined with any suitable 
DC-DC converter to facilitate a multi output ‘custom’ PSU, 
complete with PCF, harmonic compliance, and meeting 
latest IEC immunity standards.

• Wide AC input voltage range
• Power factor / harmonic correction
• 3kVAC  input / output isolation
• IEC61000-4 immunity compliance
• Wide output voltage adjustment / trim range
• Remote sense
• Current share, droop mode (PFE700S)
• Constant switching frequency
• Power on signal

PFE Series, full function

These front end converters benefitting from the additional 
control elements below, facilitate an even greater level of 
functionality, allowing the user to simply realise complex 
high power ‘custom’ PSUs using standard building blocks.

• All above bullet features and additionally
• Isolated remote on / off
• Active current share
• Auxiliary supply

AC/DC converters, front end 
converters – regulated output

Series 

PFE300S

PFE500S

PFE700S

  Output trim feature                       yes  

 

           yes 

  

    

 no

  Remote sense feature                 yes  

 

           yes                                 

 no

  Warranty 

                      2 years              2 years  

 

 2 years

  Format,   

 

      closed             closed                    

 closed 

  Industry standard  

      full brick, thru hole 

           full brick, thru hole  

 full brick, thru hole

  Basement               

      yes  

 

           yes    yes

  Input voltage range 

      85 – 264V AC   

           85 – 264V AC 

 

 85 – 264V AC

  Output voltage 

 

      12, 28 and 48V            

           12, 28 and 48V 

 

 51V (semi reg)

  Efficiency 

 

      upto 86 %  

 

           upto 86 %   

 

 upto 89 %            

  Outout current / power 

      upto 25A / 303W 

           upto 33A / 504W 

 

 upto 14A / 714W

Series 

            

PFE500F

PFE1000F

  Warranty 

                  2 years                                                                          2 years

  Format,   

                 closed           

         closed

  Industry standard                  122 x 70 x 12.7 mm, thru hole  

 

      160 x 100 x 13.4 mm, thru hole 

  Baseplate    yes 

          yes

  Output voltage 

                  12, 28 and 48V 

             12, 28 and 48V

  Input voltage range                 85 – 264V 

             85 – 264V

  Output trim feature                  yes  

 

         

       yes

  Remote sense feature             yes  

 

         

       yes

  Efficiency                                 upto 86 %                       

 

       upto 86 %

  Output current / power 

  upto 25A / 303W         

 

 

       upto 33A / 504W

Summary of Contents for F280 Series

Page 1: ...APPLICATION GUIDE...

Page 2: ...rise of intelligent products today s electronics industry is on the verge of an unprecedented new era TDK Lambda will continue to provide solid support for this ever widening range of new applications...

Page 3: ...formance quality and cost the designer is able to engineer an energy efficient cost effective and reliable distributed power architecture system to address the most demanding of needs in todays evolvi...

Page 4: ...zero airflow these POLs are ideal for all applications Very low profile 3A only 3 45 mm tall Very high efficiency upto 96 5 No Tuning required Can source or sink current Positive or negative on off lo...

Page 5: ...c choice Sequencing options SMT or SIP package choices Input Voltage Range 3 0 to 5 5V Input Voltage Range 6 0 to 14 0V Series iBA iAA Output current power 8A 26 W 15A 50W Efficiency upto 97 upto 97 O...

Page 6: ...the built in droop output regulation technique 1500V basic isolation 13 2 mm tall 12 7 mm no baseplate No baseplate option Monotonic start up Starts into pre biased load Constant switching frequency...

Page 7: ...Pin length choice Isolated remote on off Current share option droop technique Series iFB Warranty 3 years Format DOSA open frame Industry standard full brick thru hole Baseplate option Output voltage...

Page 8: ...lation Very low profile contact cooling compatibility Output voltage adjustment trim range Remote sense Monotonic start up starts into pre biased load Starts into pre biased load Constant switching fr...

Page 9: ...t voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Pin length choice Positive or negative on off logic option Series iSA iSF iSF W...

Page 10: ...uency Pin length choice SMT options Positive or negative on off logic option Series iEE iEE4W Warranty 3 years 3 years 3 years 2 years Format DOSA open frame open frame open frame open frame Industry...

Page 11: ...frequency Pin length choice Positive or negative on off logic option Series PAQ Warranty 2 years 3 years 3 years 3 years Format DOSA open frame open frame open frame open frame Industry standard B bri...

Page 12: ...tive on off logic option Current share option droop technique Series iHG PAH300 450 Warranty 3 years 2 years Format DOSA open frame closed open frame Industry standard 1 2B brick thru hole 1 2B brick...

Page 13: ...7 6 x 50 8 x 14 4 mm 3 45 x 2 x 0 57 Dual output Low output ripple and noise Sequenced output start up Monotonic start up Starts into pre biased load Constant switching frequency Positive or negative...

Page 14: ...rsatile 1500V basic isolation Very wide output voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Active current share Auxiliary sup...

Page 15: ...e 3kV AC isolation input to output Very wide output voltage adjustment trim range Remote sense Monotonic start up Starts into pre biased load Constant switching frequency Active current share Auxiliar...

Page 16: ...building blocks All above bullet features and additionally Isolated remote on off Active current share Auxiliary supply AC DC converters front end converters regulated output Series PFE300S PFE500S P...

Page 17: ...harmonic correction 3kVAC input output isolation EN60555 2 compliant Active current share Enable signal Inverter good signal Constant switching frequency N 1 redundancy AC DC converters front end con...

Page 18: ...99 Fax 1 214 239 3102 E mail support tdkinnoveta com www tdkinnoveta com TDK Corporation of America 475 Half Day Road Lincolnshire IL 60069 2934 Phone 847 699 2299 Fax 847 803 6296 www tdk com TDK Ele...