INSTRUCTION MANUAL
ZWS240RC
Series
TDKLambda
<Page>
1. Model name identification method
ZWS 240 RC
–
24
(*1)
ZWS240RC options
Blank : Standard
/R
: With remote ON/OFF control model.
/A
: With chassis and cover model.
/RA : With chassis and cover and Remote
ON/OFF control model.
2. Terminal Explanation
L : AC Input terminal (Live line)
(Fuse in line)
N : AC Input terminal (Neutral line)
: Earth terminal
Mounting hole (hole diameter :
φ
3.5mm)
These holes are connected to terminal of CN1.
Must be connected to electrically conductive spacer. The mounting surface of the spacer should be within Max
φ
8mm.
Mounting hole (hole diameter :
φ
3.5mm)
These holes are not connected to
terminal of CN1.
+
: + Output terminal
-
: Output terminal
V.ADJ : Output voltage adjustment trimmer. The output voltage rises when a trimmer is turned clockwise.
3/12
Rated Output Power
Series Name
1
2
3
8
7
6
5
4
Rated Output Voltage
Series Name