TDK-Lambda VS-E Series Instruction Manual Download Page 8

 

-7- 

TDK-Lambda 

VS-E Series 
Instruction Manual

 

6. Wiring Method 

(1)

 

The output load line and input line shall be separated each other and twisted individually to improve noise. 

(2)

 

Use all lines as thick and short as possible to made lower impedance. 

(3)

 

Noise can be reduced by attaching a capacitor to the load terminals. 

(4)

 

For safety and EMI considerations, connect

terminal of input connector and mountable Frame Ground of VS-E series to ground 

terminal equipment firmly. 

 

7. External Fuse Rating 

Refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current flows when line turns on. 
Please use slow-blow or time-lag type fuse, not fast-blow fuse. Fuse rating is specified by in-rush current value at line turn-on. Do not select 
the fuse according to input current (RMS.) values under the actual load condition 

VS50E

   

: 4.0A 

VS75E

   

: 5.0A 

VS100E : 5.0A 
VS150E : 6.3A 
 

8. Before concluding that the unit is at fault 

(1)

 

Check if the rated input voltage is connected. 

(2)

 

Check if the wiring of input and output is correct. 

(3)

 

Check if the wire thickness is enough. 

(4)

 

Check if the output current and output wattage dose not over specification. 

(5)

 

Check if the output voltage control (V.ADJ) is properly adjusted. OVP might be triggered and output is shut down. 

(6)

 

Audible noise can be heard when input voltage waveform is not sinusoidal. 

(7)

 

Ensure that a large capacitor is not connected on the output side. Please use within maximum capacitance shown below. 

 

 

Maximum external capacitance

 

MODEL

 

3.3V 

5V 

12V 

15V 

24V 

48V 

VS50E 

10,000uF 

5,000uF 

2,000uF 

500uF 

VS75E 

  VS100E 

  VS150E 

5,000uF 

30,000uF 

 

9. The life expectancy

 

The life of the power supply depends on the life of the built-in aluminum electrolytic capacitor. 
The life is described in reliability data. 
The life of the aluminum electrolytic capacitor varies depending on the method of mounting the power supply, the load current,   
and the ambient temperature. 
Please refer to "Electrolytic Capacitor Lifetime". 
Please do not use the product which passed over the life expectancy. 
There is a risk of unexpected output shutdown and specifications may not be satisfied. 
Please contact us for maintenance or exchange the product which passed over the life expectancy. 
 

10. Warranty Period

 

This product is warranted for a period of 5 years from the date of shipment. 
For damages occurring at normal operation within this warranty period, repair is free of charge. 
 
 

Summary of Contents for VS-E Series

Page 1: ...here condensation might occur In such case waterproof treatment is necessary Do not use this product in environment with a strong electromagnetic field corrosive gas or conductive substances For appli...

Page 2: ...ACInputterminal Liveline Fusein line N ACInputterminalNeutral line Terminal Protective earth Mounting hole holediameter 3 5mm Thisholeisconnected to ProtectiveEarth ofCN1 Mustbeconnected to electrical...

Page 3: ...rovenoise sensitivity Do notapply stressto PCB when connecting orremoving connector Useinput outputconnector specified by thetablebelow Use recommended crimping tool Connectorisnotincluded with thispr...

Page 4: ...to the output power line 4 5 Over Current Protection OCP VS50E Down back limiting and Hiccup mode near shorted conditions automatic recovery VS75E VS150E 3V 5V Constant current limiting and Hiccup mod...

Page 5: ...ly discharged after the test AC L AC N Isolation Tester Output Protective Earth 500VDC More than 100M 4 10 Withstand Voltage This series is designed to withstand 2 0kVAC between input and output 2 0kV...

Page 6: ...30 60 70 80 Ta Load Mounting A D 3V 24V Mounting E 3V 24V Ta Load 10 40 50 60 100 100 70 80 60 70 20 1 Mounting A D Mounting A C 1 Mounting E Mounting D E A C 48V D E 48V VS75E 100 120 80 60 40 20 0...

Page 7: ...the unit installation The vibration spec is that the unit mounted by 6mm spacers 9mm 9mm 9mm 9mm 9mm 9mm 9mm Mounting Holes size 4 holes 3 5mm Allowable area by metal pieces are 9mm from each PCB cor...

Page 8: ...put current and output wattage dose not over specification 5 Check if the output voltage control V ADJ is properly adjusted OVP might be triggered and output is shut down 6 Audible noise can be heard...