TDK-Lambda VS-E Series Instruction Manual Download Page 7

 

-6- 

TDK-Lambda 

VS-E Series 
Instruction Manual

 

FORCED AIR COOLING   
VS50E

75E

100E

150E 

100

120

80

60

40

20

0

-10

0

20

40 50

10

30

60 70 80

MOUNTING (A) - (E)  

Ta

(

)

Mounting (A) - (E)

 Load (%)

-10 - +60

+70

70

100

Ta (

)

L

oa

(%

)

The entire component must be cooled.

Electrolytic capacitor upper bound temperature

MODEL

(*1) Io

80

 Load (%)

VS50E

VS75E

100E

150E

(*2) 80

Io

100

80

75

85

80

(*1) Condition to apply 5 years warranty.
(*2) Condition to apply 3 years warranty.

 

 

The maximum temperature of the electrolytic capacitor C51 or C52 (VS50E-3 and 5 are C53) must become lower than “Electrolytic capacitor 
upper bound temperature” in the above table. Please let air 0.5m

3

/min (17.7CFM) flow into the component side as a standard.     

 

5-3. Mounting Method 

Insert the spacer (Max

φ

8.0) of height more than 6mm to lift the unit. Also use all mounting holes for the unit installation. The vibration spec 

is that the unit mounted by 6mm spacers. 
 

9mm

9mm 

9mm 

9mm

9mm 

9mm 

9mm

Mounting Holes size

 4 holes 

φ

3.5mm.

 Allowable area by metal pieces are 9mm from  
  each PCB corners.

Condition to meet Insulation & Withstand Voltage standard.

  

 Leave 3mm space from the power supply surface.  

  

 Leave 6mm space from the solder side surface.

  

 Leave 2mm space from the sides of PCB.

2mm

3mm

2mm

2mm

2mm

9mm 

6mm

 

(Protective Earth) should be connected to the earth terminal of the equipment. Also 2 mounting holes are should be connected to the 

Chassis by metal spacer. If not, the conducted noise, radiation noise and output noise will increase. 

 
 

Metal spacers

Terminal

Earth
Terminal

Wire

Input

Output

Chassis

Conductor

 

 
 

 
Consider the heat radiation and safety when the power supply is used in convection cooling. Please take a distance more than 15mm between 
the power supply and the peripheral parts. When lay out multiple units, please make sure to place 15mm or more space from each other. 

Summary of Contents for VS-E Series

Page 1: ...here condensation might occur In such case waterproof treatment is necessary Do not use this product in environment with a strong electromagnetic field corrosive gas or conductive substances For appli...

Page 2: ...ACInputterminal Liveline Fusein line N ACInputterminalNeutral line Terminal Protective earth Mounting hole holediameter 3 5mm Thisholeisconnected to ProtectiveEarth ofCN1 Mustbeconnected to electrical...

Page 3: ...rovenoise sensitivity Do notapply stressto PCB when connecting orremoving connector Useinput outputconnector specified by thetablebelow Use recommended crimping tool Connectorisnotincluded with thispr...

Page 4: ...to the output power line 4 5 Over Current Protection OCP VS50E Down back limiting and Hiccup mode near shorted conditions automatic recovery VS75E VS150E 3V 5V Constant current limiting and Hiccup mod...

Page 5: ...ly discharged after the test AC L AC N Isolation Tester Output Protective Earth 500VDC More than 100M 4 10 Withstand Voltage This series is designed to withstand 2 0kVAC between input and output 2 0kV...

Page 6: ...30 60 70 80 Ta Load Mounting A D 3V 24V Mounting E 3V 24V Ta Load 10 40 50 60 100 100 70 80 60 70 20 1 Mounting A D Mounting A C 1 Mounting E Mounting D E A C 48V D E 48V VS75E 100 120 80 60 40 20 0...

Page 7: ...the unit installation The vibration spec is that the unit mounted by 6mm spacers 9mm 9mm 9mm 9mm 9mm 9mm 9mm Mounting Holes size 4 holes 3 5mm Allowable area by metal pieces are 9mm from each PCB cor...

Page 8: ...put current and output wattage dose not over specification 5 Check if the output voltage control V ADJ is properly adjusted OVP might be triggered and output is shut down 6 Audible noise can be heard...

Reviews: