TDK-Lambda VS-E Series Instruction Manual Download Page 5

 

-4- 

TDK-Lambda 

VS-E Series 
Instruction Manual

 

4-8. Parallel Operation 

For parallel operation, method (B) is possible.   

Load

Output

Terminal

Output

Terminal

Load

Output

Terminal

Output

Terminal

(B)  To use as Back-up Power Supply 
      1. Adjust the output voltage of each power supply to be the same.
       2. Set power supply output voltage higher by the forward voltage 
          drop (Vf) of diode. 
           Use within the specification for output voltage and output power.

(A)  To increase the output current is not possible.       

Power Supply

Power Supply

 

4-9. Isolation Test 

Isolation resistance between Output - 

(Protective Earth) is more than 100M

Ω

at 500VDC. For safety operation, voltage setting of DC 

isolation tester must be done before the test. Ensure that the unit is fully discharged after the test.

 

AC(L)

AC(N)

Isolation 

Tester

+

Output -     (Protective Earth) : 500VDC  More than 100M

Ω

 

 

4-10. Withstand Voltage 

This series is designed to withstand 2.0kVAC between input and output, 2.0kVAC between input and 

(Protective Earth) and 500VAC 

between output and 

(Protective Earth) each for 1 minute. When testing withstand voltage, set current limit of the withstand voltage test 

equipment to 10mA (output - 

(Protective Earth): 20mA). The applied voltage must be gradually increased from zero to the testing value 

and then gradually decreased for shut down. When timer is used, the power supply may be damaged by high impulse voltage at timer switch 
on and off. Connect input and output as follows. 
 

AC(L)

AC(N)

+

AC(L)

AC(N)

+

Withstand

Voltage Tester

Input - Output (Dashed line) : 2.0kVAC 1min ( 10mA) 

Input -     (Protective Earth) (Solid line) : 
                                               2.0kVAC 1min ( 10mA )  

Output -      (Protective Earth) : 500VAC 1min (20mA)

Withstand

Voltage Tester

Withstand

Voltage Tester

 

Summary of Contents for VS-E Series

Page 1: ...here condensation might occur In such case waterproof treatment is necessary Do not use this product in environment with a strong electromagnetic field corrosive gas or conductive substances For appli...

Page 2: ...ACInputterminal Liveline Fusein line N ACInputterminalNeutral line Terminal Protective earth Mounting hole holediameter 3 5mm Thisholeisconnected to ProtectiveEarth ofCN1 Mustbeconnected to electrical...

Page 3: ...rovenoise sensitivity Do notapply stressto PCB when connecting orremoving connector Useinput outputconnector specified by thetablebelow Use recommended crimping tool Connectorisnotincluded with thispr...

Page 4: ...to the output power line 4 5 Over Current Protection OCP VS50E Down back limiting and Hiccup mode near shorted conditions automatic recovery VS75E VS150E 3V 5V Constant current limiting and Hiccup mod...

Page 5: ...ly discharged after the test AC L AC N Isolation Tester Output Protective Earth 500VDC More than 100M 4 10 Withstand Voltage This series is designed to withstand 2 0kVAC between input and output 2 0kV...

Page 6: ...30 60 70 80 Ta Load Mounting A D 3V 24V Mounting E 3V 24V Ta Load 10 40 50 60 100 100 70 80 60 70 20 1 Mounting A D Mounting A C 1 Mounting E Mounting D E A C 48V D E 48V VS75E 100 120 80 60 40 20 0...

Page 7: ...the unit installation The vibration spec is that the unit mounted by 6mm spacers 9mm 9mm 9mm 9mm 9mm 9mm 9mm Mounting Holes size 4 holes 3 5mm Allowable area by metal pieces are 9mm from each PCB cor...

Page 8: ...put current and output wattage dose not over specification 5 Check if the output voltage control V ADJ is properly adjusted OVP might be triggered and output is shut down 6 Audible noise can be heard...

Reviews: