![TDK-Lambda RWS 1500B Series Instruction Manual Download Page 5](http://html1.mh-extra.com/html/tdk-lambda/rws-1500b-series/rws-1500b-series_instruction-manual_4227726005.webp)
INSTRUCTION MANUAL
RWS1000B
•
1500B Series
TDKLambda
<Page>
CN83, CN84 Connector pin Configuration and Function
CN83 and CN84 are same pin configuration and function (Standard and option model exclude /S).
They are connected to each other in this power supply unit.
When the pin of CN83 side is shorted, the same function pins of CN84 side are also shorted.
Please note that the function cannot be separately set with CN83 and CN84.
* CN83, CN84 Connector (JST)
Hand Crimping Tool : YRS620 (SPHD002TP0.5) (JST) or YC610R (SPHD001TP0.5) (JST)
Use maker recommended crimping tool.
These are connected by short pieces at time of shipment.
CN83 : "+Vm" terminal (Pin No.1) to "+S" terminal (Pin No.2)
"Vm" terminal (Pin No.9) to "S" terminal(Pin No.10)
5/23
9
7
5
3
1
8
6
4
2
10
CN83,CN84
No. Configuration
Function
1
+Vm
Output monitor terminal (+V). Internally connected to +Output terminal.
(+Vm terminal can not supply load current.)
2
+S
Remote sensing terminal for +output.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to +Vm terminal when
remote sensing function unnecessary.)
3
NC
Do not connect. If connected may cause malfunction.
4
NC
Do not connect. If connected may cause malfunction.
5
NC
No connection
6
NC
No connection
7
NC
Do not connect. If connected may cause malfunction.
8
NC
No connection
9
Vm
GND for Output monitor terminal. Internally connected to Output
terminal. ( Vm terminal can not supply load current.)
10
S
Remote sensing terminal for output.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to Vm terminal when
remote sensing function unnecessary.)
Housing
Terminal Pin
PHDR10VS
SPHD002TP0.5 (AWG24 ~ 28) or
SPHD001TP0.5 (AWG22 ~ 26)
Connector
S10BPHDSS