BEFORE USING THE POWER SUPPLY UNIT 

Be sure to read this instruction manual thoroughly before using this product. 
Pay attention to all cautions and warnings before using this product.  
Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

 

 

 

DANGER

 

Never use this product in locations where flammable gas or ignitable substances are present.  
There are risks of igniting these substances and exploding by an arcing. 

 

 WARNING

 

·

 

Do not touch this product or its internal components while circuit is live, or shortly after shut down. There may be high voltage or high temperature 

present and you may receive an electric shock or burn. 

·

 

When this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

·

 

Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty. 

·

 

Do not drop or insert anything into this product. It might cause a failure, fire and electric shock. 

·

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. It might lead to fire and electric shock. 

In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the user. 

·

 

Do not operate these products in the presence of condensation. It might lead fire or electric shock. 

 

 

CAUTION

 

·

 

This power supply is designed and manufactured for use within an end product such that it is accessible to SERVICE ENGINEERS only. 

·

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

·

 

Input voltage, Output current & power, Ambient temperature & humidity should be kept within specifications, otherwise the product will be damaged. 

·

 

Do not operate and store this product in an environment where condensation might occur. In such case, waterproof treatment is necessary. 

·

 

Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances. 

·

 

For applications, which require very high reliability (Nuclear related equipment, medical equipment, traffic control equipment, etc.), 

it is necessary to provide a fail-safe mechanism in the end equipment. 

·

 

Do not inject abnormal voltages into the output of this product. The injection of reverse voltage or over voltage exceeding nominal output voltage 

into the output terminal might cause damage to internal components. 

·

 

Never operate the product under over current or short-circuit conditions for more than 30 seconds, or outside its specified Input Voltage Range. 

Insulation failure, smoking, burning or other damage may occur. 

·

 

When using commercial AC line (greater than 115VAC) of system level which has this product inside, please connect the input terminal 

of this product through AC/DC PSU (or Rectifier Unit) which has reinforced or double insulation. 

·

 

This product has Input Surge (Inrush) Current Suppressor inside. Frequent repetition of input might cause damage to internal components  

because of generating surge current by no operation of the suppressor circuit. 

·

 

Breaking of internal fuse is considered internal failure. In such cases, please contact us. 

·

 

The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, etc., for the most up-to 

date specifications of the product. 

·

 

No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda. 

 

Summary of Contents for RDS Series

Page 1: ...instruction manual before switching on Input voltage Output current power Ambient temperature humidity should be kept within specifications otherwise the product will be damaged Do not operate and sto...

Page 2: ...ion 5 6 5 OCP Over Current Protection 5 6 5 OTP Over Temperature Protection 5 6 7 Remote Sensing Function S S terminals 5 6 8 Remote Control ON OFF Function 5 6 9 Output Ripple Noise Voltage 6 6 10 Se...

Page 3: ...ut Voltage Rated Input Voltage Output Power Type Products Series Name 2 Block Diagram Note For the 5V output model Rectifier is Synchronous type and LVP function is built in Abbreviation Symbol OCP Ov...

Page 4: ...bout 5 6V at open mode It changes 0V when turning off input 4 For 5V output model OCP method is constant current limit with latch shutdown by LVP It can be reset as the 2 above Furthermore for 12 15 a...

Page 5: ...t S to V and S to V terminal 1 Remove the short piece originally attached by using the short piece sheet metal 2 Connect S V terminal by wiring Short piece is attached when shipping 3 Connect S V term...

Page 6: ...own OCP operates if output current exceeds the rated output current of the unit approximately at 120 typ Then if output decrease to 2V approximately the output will be shut down by LVP inside After LV...

Page 7: ...aximum forward current rating more than output load current And maximum reveres voltage must withstand each power supply output voltage 6 11 Parallel Operation The RDS50 110 can be used for Back up Op...

Page 8: ...nting Method etc 7 1 Mounting Directions Mounting directions are as the picture shown below Standard mounting is A However the mounting as B C is also available Do not mount using D E method Use RDS a...

Page 9: ...ct the fuse according to input average current values under the actual load condition RDS unit has same rating fuse inside Vin Line RDS50 110 F3 2AL 10 Before Thinking that the Unit is Failure 1 Check...

Page 10: ...by this handbook indicates compliance with the Low Voltage Directive and RoHS Directive UKCA MARKING UKCA Marking when applied to a product or packing material for a product covered by this handbook i...

Reviews: