 -8- 

TDK-Lambda 

RDS Series (110VDC Input) 

Instruction Manual

 

 

7-3. Precaution for Unit Mounting 

(1) The basic cooling method is Natural Convection.  Keep a space more than 15mm each around RDS unit to avoid hot air from  

accumulating.  And same application is also needed when using multiple RDS units. Please apply wind direction along the fin 

of RDS unit when using by Air-Forced cooling. 

(2) Connect  Protective Earth Terminal ( ) to the Ground of the application equipment. Otherwise, noise * will get worse. 
     ( * Input conducted emission noise, Radiated Emission noise, or  Output noise ) 
(3) Insert stroke length of a fixing screw is less than 7mm. Avoid inserting failed screw. 
(4) Recommended fastening torque for fixing 

 

     M3 type screw   :    0.51N

m  (5.2 kgf

cm) 

     M4 type screw   :    1.27 N

m  (13.0 kgf

cm) 

 

 
 
 
 
 

8. Wiring Method 

(1)  Separate wire for input & output (load) line. Further, by twisting wire for each input & output to improve switching noise. 
(2) Use short length and thick wires for input & output line in order to lower down line impedance  
(3) Switching noise will decrease by adding capacitor to load terminal. 
(4) Connect protective earth terminal ( ) to ground of the equipment by using thick wires. 
 

9. External Fuse Rating 

Please refer to the following fuse rating when selecting the external fuses that are to be used on input line. Surge current flows when line 
turns on. Fuse rating is considered by in-rush current value at line turn-on. Do not select the fuse according to input average current 
values under the actual load condition. RDS unit has same rating fuse inside (+Vin Line). 

RDS50 -110   

  F3.2AL 

 

10. Before Thinking that the Unit is Failure 

(1)

 

Check if the rated input voltage is applied. 

(2)

 

Check if the wiring of input or output line is correct. 

(3)

 

Check if the terminal screw is fastened with specified torque certainly. 

(4)

 

Check if the wire thickness is enough. 

(5)

 

Check if the output current and output power does not exceed specification. 

(6)

 

Check if the output voltage setting (V.ADJ) is properly adjusted. OVP might be triggered and output will shut down. 

(7)

 

Check if sensing wire opened or not. OVP might be triggered and output will shut down. 

(8)

 

Check if remote ON/OFF (CNT/TOG) terminal is opened or not. Output turns off if the terminal is opened. 

(9)

 

Audible noise can be heard depending on frequency or current change rate condition during Dynamic-Load operation. 

 

11. Warranty Period 

Warranty period is 5 years.  Free of charge repair is available for the damage under normal usage during warranty period. 
Free of charge warranty covers following condition. 

(1) Average ambient temperature is less than 40

o

C. 

(2) Average load is less than 80% rate of nominal output power. 
(3) Mounting method is (A), standard mounting. 

 

 

 

Following cases are not covered by warranty. 

(1) Improper usage like dropping products, applying shock, improper handling and operation exceeding maximum specification of the units. 
(2) Defects resulting from natural disaster (fire, flood etc). 
(3) Defects resulting from modifications or repair done by unauthorized or uncertified personnel by TDK-Lambda. 

 
 

Summary of Contents for RDS Series

Page 1: ...instruction manual before switching on Input voltage Output current power Ambient temperature humidity should be kept within specifications otherwise the product will be damaged Do not operate and sto...

Page 2: ...ion 5 6 5 OCP Over Current Protection 5 6 5 OTP Over Temperature Protection 5 6 7 Remote Sensing Function S S terminals 5 6 8 Remote Control ON OFF Function 5 6 9 Output Ripple Noise Voltage 6 6 10 Se...

Page 3: ...ut Voltage Rated Input Voltage Output Power Type Products Series Name 2 Block Diagram Note For the 5V output model Rectifier is Synchronous type and LVP function is built in Abbreviation Symbol OCP Ov...

Page 4: ...bout 5 6V at open mode It changes 0V when turning off input 4 For 5V output model OCP method is constant current limit with latch shutdown by LVP It can be reset as the 2 above Furthermore for 12 15 a...

Page 5: ...t S to V and S to V terminal 1 Remove the short piece originally attached by using the short piece sheet metal 2 Connect S V terminal by wiring Short piece is attached when shipping 3 Connect S V term...

Page 6: ...own OCP operates if output current exceeds the rated output current of the unit approximately at 120 typ Then if output decrease to 2V approximately the output will be shut down by LVP inside After LV...

Page 7: ...aximum forward current rating more than output load current And maximum reveres voltage must withstand each power supply output voltage 6 11 Parallel Operation The RDS50 110 can be used for Back up Op...

Page 8: ...nting Method etc 7 1 Mounting Directions Mounting directions are as the picture shown below Standard mounting is A However the mounting as B C is also available Do not mount using D E method Use RDS a...

Page 9: ...ct the fuse according to input average current values under the actual load condition RDS unit has same rating fuse inside Vin Line RDS50 110 F3 2AL 10 Before Thinking that the Unit is Failure 1 Check...

Page 10: ...by this handbook indicates compliance with the Low Voltage Directive and RoHS Directive UKCA MARKING UKCA Marking when applied to a product or packing material for a product covered by this handbook i...

Reviews: