TDK-Lambda
PFE300SA
C274-01-02
BASIC CONNECTION
F1
AC250V 15A
C13
1000pF
C1
AC250V 1uF (Film)
12V: 25V 1000uF (Elec.)
C2
4700pF
C14
28V: 50V 470uF (Elec.)
C3
4700pF
48V: 100V 220uF (Elec.)
C4
AC250V 1uF (Film)
C15
100V 2.2uF (Ceramic)
C5
AC250V 1uF (Film)
12V: 25V 1000uF (Elec.)
C6
1000pF
C16
28V: 50V 470uF (Elec.)
C7
1000pF
48V: 100V 220uF (Elec.)
C8
450V 1uF (Film)
R1
0.5W 470k
W
C9
450V 1uF (Film)
TFR1 10
W
139°C (Res., Thermal fuse)
C10
450V 470uF
L1
6mH
C11
0.033uF
L2
6mH
C12
0.033uF
==NOTES==
*1. Use an external fuse of fast blow type for each unit.
*2. The allowable ripple current of capacitor must be more than 3A(rms).
*3. Put this capacitor near the terminal as close as possible.
*4. The maximum capacitance that can be used is less than 1200uF(Rated capacitance).
Avoid the connection of capacitance which is more than above, else it will lead to
module to damage.
*5. The inrush current at AC throw in can be suppressed by the external Resistor
(Built-in thermal fuse) connected between the R and +BC terminals.
*6. If the ambient temperature is less than -20°C, use twice the recommended capacitor above.
*7. Refer to instruction manual for further details.