background image

    

TDK-Lambda

PFE300SA

C274-01-01A

SPECIFICATIONS

MODEL

 

ITEMS

1  Nominal Output Voltage

V

12

28

48

2  Maximum Output Current

A

25

10.8

6.3

3  Nominal Output Power

W

300

302.4

302.4

4  Efficiency (Typ.) 

(*1)

%

84 / 85

87/ 89

88 / 90

5  Input Voltage Range

(*2)(*5)(*9)

-

85 - 265 VAC

6  Input Frequency

(*2)

Hz

47 - 63

7  Input Current

(*1)

A

3.8 / 1.9

3.7 / 1.8

3.6 / 1.8

8  Power Factor

(*1)(*5)

-

0.95 min

9  Output Voltage Accuracy

(*1)

%

+/-2

10  Output Voltage Range

%

-20 / +20

11  Maximum Ripple & Noise 

(*5)

mV

120

280

480

12  Maximum Line Regulation

mV

48

56

96

13  Maximum Load Regulation

mV

48

56

96

14  Over Current Protection 

-

105% - 140% (Automatic recovery method)

15  Over Voltage Protection 

-

125% - 145% (Inverter shutdown method)

16  In-rush Current (Typ.)

(*1)(*5)(*6)

A

20A / 40A peak

17  Parallel Operation       

-

-

18  Series Operation

(*7)

-

Possible

19  Operating Temperature 

(*3)(*8)

-

20  Operating Humidity

-

 20 - 95%RH (No Dewdrop)

21  Storage Temperature

-

-40°C - +100°C

22  Storage Humidity

-

 10 - 95%RH (No Dewdrop)

23  Cooling

(*4)

-

Conduction Cooled 

24  Temperature Coefficient

-

Less than 0.02% / °C

25  Withstand Voltage 

-

Input-Baseplate : 2.5kVAC, Input-Output : 3.0kVAC for 1min.

Output-Baseplate : 1.5kVDC for 1min.

26  Isolation Resistance

-

Output to Baseplate 500VDC more than 100M

W

 (25°C,70%RH)

27  Vibration

-

At No Operating, 10-55Hz (Sweep for 1min.)

Amplitude 0.825mm Constant (Maximum 49.0m/s

2

)   X,Y,Z 1 hour each

28  Shock

-

196.1m/s

2

29  Safety

-

Approved by UL60950-1,CSA60950-1,EN60950-1

30  Weight (Typ.)

g

200

31  Size (W x H x D)

mm

61 x 12.7 x 116.8 (Refer to Outline Drawing)

*Read instruction manual carefully, before using the power supply unit.

Derating Curve

 =NOTES=
 *1. At 100VAC/200VAC and maximum output power.
       (Baseplate Temperature = +25°C.)
 *2. For cases where conformance to various safety specs
       (UL, CSA, EN) are required, input voltage range 
       will be 100 - 240VAC(50 - 60Hz).
 *3. Ratings - refer to Derating Curve on the right.
 *4. Heatsink has to be chosen according to Instruction manual.
 *5. External components are needed for operation.
       (Refer to basic connection and instruction manual.)
 *6. First inrush current. Not applicable for the inrush current to 
       Noise Filter for less than 0.2ms.
 *7. Refer to Instruction manual.
 *8. Ambient Temperature min=-40°C.
 *9. Start-up at Vin=83VAC guaranteed.

PFE300SA-12

PFE300SA-28

PFE300SA-48

-40°C - +100°C

0

20

40

60

80

100

-40

-20

0

20

40

60

80

100

L

oa

 (

%

Baseplate Temperature (

)

Reviews: