3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4

LZS-A

A500-33  Power  Supply

Revision K : December 2009

Page. 3

Emissions

Table    1

AC Line Conducted Emissions

EN55022/EN55011

(0.15-30 MHz) Class B

Radiated RF Emissions

EN55022/EN55011

30-1000 MHz Class B

Powerline Harmonics

EN61000-3-2

Class A Limits

Powerline Fluctuation/Flicker

EN61000-3-3

Complies

Immunity

Electrostatic Discharge

IEC61000-4-2

+/-8 kV Air

+/-6 kV Contact

RF Radiated Fields

IEC61000-4-3

10 V/m, 80 MHz-2.5GHz

80% AM @ 1kHZ

Electrical Fast Transients

IEC61000-4-4

+/-2 kV AC Line, Criteria A

+/-1 kV I/O Line > 3m, Criteria A

Lightning Surge

IEC61000-4-5

+/-2 kV line to GND (CM), Criteria A

+/-1 kV line to line (DM), Criteria A

Conducted RF Common Mode

IEC61000-4-6

10 V/m RMS, 150 kHz-80 MHz

80% AM at 1kHz

Power Frequency Magnetic Field

IEC61000-4-8

3 A/m

Voltage Dips/Short Variations

IEC61000-4-11

5% of nom. line for .5 cycles - Criteria A

40% for 5 cycles - Criteria A

70% for 25 cycles - Criteria A

95% Dip for 5 seconds -

Unit should not latch

SEMI-F47 (100 VAC)

50% of nom. line for 200 msec

70% for 500 msec

80% for 10 seconds

90% for 15 seconds

0% for 1 cycle or 20mS

Additional Immunity

Ring Wave Lightning Surge Test

IEEE C62.41

6 kV/30 Ohm Criteria A

Summary of Contents for LZS-A500-3

Page 1: ...LZS A500 3 POWER SUPPLY Installation Operation and Maintenance Manual IM L LZSA500 3 3 December 2009 Revision K...

Page 2: ......

Page 3: ...Practices 2 1 1 General safety instructions 2 1 2 Safety Agency Approvals 2 2 RATINGS AND SPECIFICATIONS 4 3 FEATURES 5 4 GUIDE TO APPLICATION 7 4 1 Safety Notice 7 4 2 Input Voltage 7 4 3 Output Volt...

Page 4: ...Therefore screws at the case must not be removed or loosened 7 The output power taken from the power supply must not exceed the rating stated on the power supply label 8 Openings in the product case a...

Page 5: ...cal Fast Transients IEC61000 4 4 2 kV AC Line Criteria A 1 kV I O Line 3m Criteria A Lightning Surge IEC61000 4 5 2 kV line to GND CM Criteria A 1 kV line to line DM Criteria A Conducted RF Common Mod...

Page 6: ...PR 22 Class B Efficiency at max output power 84 typical 110VAC line Output Performance Specifications Units LZS A500 3 Table 4 Voltage Line Regulation 0 1 Voltage Load Regulation 0 1 Ripple and Noise...

Page 7: ...able output via TTL compatible signal connected between pins 6 and 7 of D connector see Fig 9 Signals Isolation Pins 6 and 7 are fully isolated from all other power supply terminals Signal Logic Logic...

Page 8: ...urface mounting position not restricted Maximum allowable penetration into power supply is 1 4 Requires No M4 metric hardware supplied with unit Input and Output Connections Table 11 Input Heavy duty...

Page 9: ...point When adjusting the output voltage above 24 0V ensure that there is sufficient OVP margin with respect to the output voltage to avoid nuisance tripping 4 4 OVERVOLTAGE PROTECTION CIRCUIT ADJUSTM...

Page 10: ...Revision K December 2009 Page 8 LZS A A500 3 3 Power Supply Figure 1 PIN Assignments for TB201 and chassis mounted D connector 5 Figures...

Page 11: ...o CA 92154 1 800 LAMBDA 4 LZS A A500 3 3 Power Supply Revision K December 2009 Page 9 Figure 3 Typical Remote Sense Connection Figure 2 Typical Local Sense Connection LS Local Sense S Remote Sense LS...

Page 12: ...gure 5 Remote Voltage Control with an External Programming Resistor or Voltage Source Remote Sensing Figure 4 Remote Voltage Control with an External Programming Resistor or Voltage Source Local Sensi...

Page 13: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A500 3 3 Power Supply Revision K December 2009 Page 11 Figure 6 Parallel Operation...

Page 14: ...LZS A A500 3 3 Power Supply Revision K December 2009 Page 12 Figure 7 Series Operation...

Page 15: ...3055 Del Sol Blvd San Diego CA 92154 1 800 LAMBDA 4 LZS A A500 3 3 Power Supply Revision K December 2009 Page 13 Figure 8 Outline Drawing AIR FLOW...

Page 16: ...LZS A A500 3 3 Power Supply Revision K December 2009 Page 14 Figure 9 Remote Output On Off Control Figure 10 Input Good Inverter Good Output Good Signals...

Reviews: