5-11. Parallel Operation
Current balancing function is provided. Either of operations mode (A) or (B) is possible.
(
A
)
To Increase the Output Current
Current balancing function activates by connecting PC-to-PC terminal and COM-to-COM terminal, and output current
of each power supply is equivalently supplied to load. Wires to PC terminals shall be as short as possible, same length
and twisted.
There is a possibility that output could be unstable caused by external noise. For this case, disconnect COM terminal
and connect -S terminal from parallel power supply to a single point on the load. Please refer connection Method (A)-2.
1.
Adjust the output voltage of each power supply to be same value within 1% or 100mV, whichever is smaller.
2.
Use same length and type of wires for all load lines.
3.
Maximum value of output current in parallel is up to 80% of all paralleled models. The purpose of the current
balancing function is the static power-up. Therefore the output voltage might decrease according to the
condition of dynamic load. There might be a step in the rise waveform during parallel operation.
4.
Up to 5 units can be connected in parallel.
(
B
)
To Use as a Backup Power Supply
1.
Set power supply output voltage higher by the forward voltage drop of diode.
2.
Adjust the output voltage of each power supply to be same value.
3.
Use within the specifications for output voltage and output power.