Example: OUTP:PROT:CLE
8.5 Programming the Output Voltage
This command sets the Voltage Limit.
Syntax: VOLT<nn.nn>
VOLT?
Parameter: nn.nn. Please refer to HFE User Manual (/S option) for the range of
Voltage programming for each model.
Example:
VOLT 46.5
Query:
VOLT? Will return 46.5 in the example.
Errors:
SYSTEM:ERROR? May return:
“Data out of range”
8.6 Programming the Current Limit (HFE2500/S only)
This command sets the Current Limit.
Syntax: CURR<nn.nn>%
CURR?
Parameter: nn.nn. Please refer to HFE User Manual (/S option) for the range of
Current programming for each model.
Example:
CURR 90%
Query:
CURR? Will return 90% in the example.
Errors:
SYSTEM:ERROR? May return:
“Data out of range”
“Percentage Symbol Missing”
8.7 Programming the Maximum allowed Programmable Output Voltage
This command is used to set the maximum Allowed Voltage. This acts as a Voltage limiter
and does not allow the Voltage to be programmed to higher than this value. (refer to table 7)
Syntax:
VOLT:PROT:LEV <nn.nn>
VOLT:PROT:LEV?
Parameter: nn.nn - 12V Supply – 15V, 24V Supply – 30V
32V Supply – 40V, 48V Supply – 60V
These are maximum values.
Example:
VOLT:PROT:LEV 46
Query:
VOLT:PROT:LEV? Will return 46 in the example.