2.8.11 READ QUESTIONABLE INSTRUMENT SUMMARY ‘EVENT’ REGISTER COMMAND
See Figure 6 and Section 2.9.8,
THE SUMMARY REGISTERS
. Read which supplies sent
an SRQ. These bits are set regardless of the value of the enable bit. When set they remain set
until read.
Syntax:
STATus:QUEStionable:INSTrument:ISUMmary1? or
STATus:QUEStionable:INSTrument:ISUMmary2? or
STATus:QUEStionable:INSTrument:ISUMmary3?
Example:
STAT:QUES:INST:ISUM1?
2.8.12 STATUS PRESET COMMAND
Presets all Operation Enable and Questionable Enable Registers.
Syntax:
STATus:PRESet
Example:
STATUS:PRESET
2.9 USING ERROR AND STATUS REGISTERS
2.9.1 OVERVIEW: REGISTER FAN-OUT
7KH ,((( ,QWHUIDFH ERDUG KDV D VHW RI VWDWXV DQG HUURU UHJLVWHUV 7KH\ DUH GH¿QHG E\ WKH
,(((VSHFL¿FDWLRQDVSDUWRIWKH,(((&RPPRQ&RPPDQGVHWUHTXLUHGE\DOOFRP
-
pliant instruments.
These registers allow the IEEE controller to examine the operational state of the supply in detail.
A “fan-out” architecture is used so only one summary register needs to be read to know if an
HYHQWRFFXUUHGLQDQ\RWKHUUHJLVWHU7KLVIDQRXWDOORZVDXWRPDWLFWHVWSURJUDPVWRHI¿FLHQWO\
manage the remote programming mode.
A diagram of the register structure is shown in Figure 4 for Point-to-Point Mode and in Figure 5
and Figure 6 for Multi Drop Mode.
2.9.2 GLOSSARY OF REGISTER TERMS
SERVICE REQUEST: When an instrument on the IEEE bus asserts the SRQ line
in the cable, it tells the controller that it has completed its task or that an error has
occurred.
SERIAL POLL: An IEEE function which reads back the data in an instrument’s
Status Byte Register. The controller should perform this function after every com-
mand to verify the command was successful.
REGISTER QUERIES: Read the contents of registers. The contents are returned
as a binary weighted decimal number.
CONDITIONAL REGISTERS. These contain bits that are set when a condition or
error occurs. The bits are only cleared when the condition or error is cleared. The
contents may be read but not changed.
ENABLE REGISTERS: The various Enable Registers can be set to allow the sta-
tus and errors to be detectable by a Serial Poll.