2.3.7 GLOBAL SAVE POWER SUPPLY SETTINGS COMMAND
Sends a command to all Power Supplies causing them to save their operating set-
tings:
Programmed voltage, Current, Over Voltage, Under Voltage, Remote/Local Mode,
Auto/Safe Restart, Current Fold Back, etc. can be
stored in Memory.
To change one or more settings, enter the one or more commands with new settings
and then enter this command.
Syntax:
GLOBal:*SAV<SP><0>
Example:
GLOBAL:*SAV 0
2.3.8 GLOBAL RECALL POWER SUPPLY SETTINGS COMMAND
Sends a command to all Power Supplies causing them to recall their operating set-
tings:
Recall Programmed voltage, Current, Over Voltage, Under Voltage, Remote/Local
Mode, Auto/Safe Restart and Current Fold Back. If the output of the supply was set
to an OFF condition by the Front Panel Button before the *RCL command was sent,
the supply will remain in the OFF state.
Syntax:
GLOBal :*RCL<SP><0>
Example:
GLOBAL :*RCL 0
2.4 OUTPUT PROTECTION COMMANDS
2.4.1 OVER
VOLTAGE PROTECTION
2.4.1.1 SET THE OVER VOLTAGE PROTECTION LEVEL COMMAND
Set the over voltage protection level of the Power Supply to <value>, where <value> is a number
between zero and the maximum supply output voltage. A decimal point is optional.
Syntax:
[SOURce]:VOLTage:PROTection:LEVel<SP><value>
Alternate Format:
:VOLTAGE:PROTECTION:LEVEL<SP><value>
Examples:
SOURCE:VOLTAGE:PROTECTION:LEVEL 25.00
SOURCE:VOLTAGE:PROTECTION:LEVEL MAX
Notes:
If <value> equals MAX, the supply will set its over voltage to its maximum level.
Summary of Contents for Genesys Series
Page 1: ...6 3 3 0XOWL URS QWHUIDFH 2SWLRQ...
Page 2: ...USER MANUAL FOR IEEE PROGRAMMING INTERFACE FOR GENESYSTM POWER SUPPLIES 5HY...
Page 3: ...7KLV SDJH LQWHQWLRQDO OHIW EODQN...
Page 40: ...NOTES...
Page 41: ...NOTES...