33
83503001 Rev G
3.3. Initial Inspection
Prior to shipment this power supply was inspected and found free of mechanical or electrical
defects. Upon unpacking of the power supply, inspect for any damage, which may have occurred
in transit.
The inspection should confirm that there is no exterior damage to the power supply such as
broken knobs or connectors and that the front panel and meter’s faces are not scratched or
cracked. Keep all packing material until the inspection has been completed. If damage is
detected, file a claim with carrier immediately and notify the TDK-Lambda Americas Inc. sales or
authorized service facility nearest you.
3.4. Rack Mounting
The Genesys
TM
power supply series is designed to fit in a standard 19” equipment rack.
3.4.1. To install the Power Supply in a Rack:
1. Use the front panel rack-mount brackets to install the power supply in the rack.
2. Use a support bar to provide adequate support for the rear of the power supply. Do
not obstruct the air exhaust at the rear panel of the unit.
3.4.2. Rack Mount Slides (optional):
CAUTION
Ensure that the screws used to attach the slides to the unit do not penetrate
more than 6mm into the sides of the unit.
Use rack mount slides: General Devices P/N: C-300-S-116 or equivalent to install the
unit in a standard 19” equipment rack. Refer to Fig. 3-1 for slides assembly instructions.
Use three #10-32x0.38” (max.) screws at each side. To prevent internal damage, use
the specified screw length only.
3.4.3. Plastic Supporting Legs
Use the four plastic legs supplied with the unit, when the power supply is mounted on a
surface or when units are stacked without rack support. When using the plastic legs,
maximum three units can be stacked.