25
83503001 Rev G
Remote sensing to compensate for voltage drop of power leads.
External Analog Programming and Monitoring standard (0-5V or 0-10V, user
selectable).
Cooling fan speed control for low noise and extended fan life.
Zero stacking-no ventilation holes at the top and bottom surface of the power
supply.
Optional GPIB interface (SCPI compatible).
Optional Isolated Analog programming/monitoring (0-5V or 0-10V, user selectable
and 4-20mA).
1.2.4.
Multiple Output Power System
The Genesys
TM
power supplies series can be configured into a programmable power
system of up to 31 units using the built-in RS232/RS485 communication port and the
RS485 linking cable provided with each power supply.
In a GPIB system, each power supply can be controlled using the optional GPIB
controller (factory installed).
1.2.5.
Control via the serial communication port
The following parameters can be programmed / monitored via the serial communication
port:
a) Output Voltage setting.
b) Output Current setting.
c) Output Voltage measurement.
d) Output On/Off control.
e) Output Current measurement.
f)
Foldback protection setting.
g) Over-voltage protection setting and readback.
h) Under-Voltage limit setting and readback.
i)
Power-supply start up mode (last setting or safe mode).
1.2.6.
Analog Voltage Programming and Monitoring
Analog inputs and outputs are provided at the rear panel for analog control of the
power supply. The Output Voltage and the Current can be programmed by analog
voltage or by resistor and can be monitored by analog voltage. The power supply
output can be remotely set to On or Off and analog signals monitor the proper
operation of the power supply and the mode of operation (CV/CC).
1.2.7.
Parallel Operation
Genesys
™
power supplies of the same Output Voltage and Current rating can be
paralleled in a master-slave configuration with automatic current sharing to increase
power available.