background image

10. Maintenance

Periodically check all external cable connections.

11. Cleaning

Observe the safety instructions before cleaning the device. Clean the device with a
dry lint-free soft cloth. Do not use solvents.

12. Specification

DPM72-MPPA

Supply

12 - 24 V AC/DC ±10% (50/60 Hz ±10%) or if

applicable via USB, galvanically isolated

Power consumption

Max. 2.4 W

Display

LCD graphic display 192 × 160 pixels,

16 grey levels with RGB backlight

Measuring range ampere

20 mA AC/DC (max. 100 mA), 10 - 500 Hz

Accuracy ampere

±0.5 % true RMS

Internal resistance ampere

6.2 Ω

Measuring value update

5 Hz (32 kHz sampling rate)

Recording of measurement

36 seconds to 14 days,

180 internal memory locations

Alarm outputs

2 optocoupler outputs max. 30 V DC, 50 mA

Permissible voltage between
supply and measuring inputs

< 50 V AC, < 75 V DC

Connections
(measuring inputs)
- Wire gauge
- Wire strip length
- Pitch

0.2 - 3.3 mm² (24 to 12 AWG)

7 - 8 mm

7.62 mm

Connections (supply, alarm 
outputs and RS485)
- Wire gauge
- Wire strip length
- Pitch

0.13 - 1.3 mm² (26 to 16 AWG)

6 - 7 mm

3.5 mm

Operating temperature

0 °C to +50 °C

Storage temperature

-20 °C to +70 °C

Operating altitude

0 to 2000 m above sea level

IP code

IP65 (front), IP00 (back)

Dimensions

72 mm × 72 mm × 58 mm

Panel cut-out

68 mm × 68 mm

Mounting depth

55.3 mm (with plugs, cable direction rear facing)

72.6 mm (with antenna)

Net weight

148 g

-----

 7 / 8 

-----

Summary of Contents for Digalox DPM72-MPPA

Page 1: ...t The device must not be used as the only protective device or protective shutdown The device is not intended to protect persons or facilities against harm Specific devices must be used to guarantee s...

Page 2: ...onds up to 14 days The time base as well as the display of the measuring history can be switched by an external switch The measured values remain stored as long as the device is supplied with voltage...

Page 3: ...4 Back 1 2 optocoupler switch outputs 2 Jumper pins J1 J12 for activating switching of graphical historic data display min max display auto scaling display value mode 3 Supply voltage input 4 Interfa...

Page 4: ...alogue signal Digalox I2low I2high I1high I1low max 100 mA FF 100 mA Sensor Supply sensor 0 mA 20 mA 2 20 mA analogue signal Digalox max 100 mA FF 100 mA I2low I2high I1high I1low max 100 mA FF 100 mA...

Page 5: ...puter using an RS485 USB adapter After completing the configuration open J8 again Start the Digalox Manager software and connect it to the device Settings can then be made on the various tabs and save...

Page 6: ...nterval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting perman...

Page 7: ...date 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Alarm outputs 2 optocoupler outputs max 30 V DC 50 mA Permissible voltage between supply and...

Page 8: ...information TDE Instruments GmbH Gewerbestra e 8 D 71144 Steinenbronn Phone 49 7157 20801 E mail info tde instruments de Internet www tde instruments de www digalox com 8 8 56 3 83 5 72 0 72 0 77 5 18...

Reviews: