background image

 

Digalox DPM72-MPPA

Instruction manual (Rev-2020-11)

Graphical panel meter with RGB backlight for analogue signal 2 × 0/4 - 20 mA

Package contents:

Panel meter Digalox DPM72-MPPA, mounting bracket,
5 jumpers, 2 instruction manuals (EN + DE)

1. Safety instructions

Read   instruction   manual   carefully   before   operating   the   device!   Keep   for   later
reference.

Mounting and installation must be carried out by suitably qualified and competent
persons only.

When working on the device hazardous voltages must not be connected to
the   device!   The   terminals   J1-J12   are   not   isolated   from   the   measuring
circuit.

The device must not be used as the only protective device or protective
shutdown.

The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).

When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 30 V DC switches must be isolated for at
least 60 V.

Do not open the housing!

Do not use the device in the presence of explosive or flammable substances!

All cables carrying hazardous voltages must be secured with external separators.

2. Meaning of symbols

General warning sign
(Attention, observe the documentation!)

Warning of an electrical hazard

-----

 1 / 8 

-----

Summary of Contents for 103317

Page 1: ...t The device must not be used as the only protective device or protective shutdown The device is not intended to protect persons or facilities against harm Specific devices must be used to guarantee s...

Page 2: ...recorded over a timespan of 36 seconds up to 14 days The timebase as well as the display of the measuring history can be activated by an external switch The measured values remain stored as long as t...

Page 3: ...3 2 1 5 4 Back 1 2 optocoupler switch outputs 2 Jumper pins J1 J12 for activating switching of graphical historic data display min max display auto scaling measurement mode 3 Supply voltage input 4 In...

Page 4: ...sensor with voltage supply 20 mA analogue signal I2low I2high I1high I1low max 100 mA 0 mA 20 mA FF 100 mA 2 20 mA analogue signal max 100 mA 0 mA 20 mA FF 100 mA I2low I2high I1high I1low max 100 mA...

Page 5: ...t the Digalox Manager software and connect it to the device Settings can then be made on the various tabs and saved in the device Please note that the measurement mode selected in Digalox Manager is d...

Page 6: ...interval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting perm...

Page 7: ...pdate 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Alarm outputs 2 optocoupler outputs max 30 V DC 50 mA Permissible voltage between supply an...

Page 8: ...information TDE Instruments GmbH Gewerbestra e 8 D 71144 Steinenbronn Phone 49 7157 20801 E Mail info tde instruments de Internet www tde instruments de www digalox com 8 8 56 3 83 5 72 0 72 0 77 5 18...

Reviews: