14
07/2013
TCS TürControlSysteme AG
Subject to technical changes.
Mail: [email protected]
ISH3030-0140 UK 2A
20 Ohm:
max. 160 m distance AS/IS-VS at 0.6 mm diameter
max. 300 m distance AS/IS-VS at 0.8 mm diameter
AS front-door station
VS power supply and control unit
IS
indoor station
FE
extended function
Repair
Error detection and indication
Errors will be indicated optical and acoustic: error tone for one time and constant flashing
of the operation indication. When pressing any button, the error tone sounds again. The
optical error indication stays active as long as the error is resolved.
error causes
display
error
mode
error tone elimination
a- and P-wire interchanged
or short-circuited
both
LEDs
are
flashing
change a- and P-wire or eliminate short-circuit,
device is going into sleep mode again
a-wire: not connected or
not supplied
Connect the a-wire or proof power supply,
device is going into sleep mode again
button stucks
(pressed longer than 15 s)
Remove button at the device or floor push button,
device is going into sleep mode again
Substitution of an indoor station
– programming bell buttons
Basic principle
All devices at the TCS:BUS got an unique serial number.
Programming a bell button means that the serial number of an indoor station is allocat-
ed to the bell button of a front-door station and is stored within the EEPROM of the
front-door station.
Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage
is switched on (the operation LED at the power supply and control unit is ON) and fur-
ther, that the access to the flat is guaranteed during the programming.
This instruction describes the case, when a serial number is allocated to a bell button
and no programming lock is set. To unlock a programming lock you need a Service De-
vice TCSK-01or the configuration software configo
™.
a, b hier
kurzschließen