Connection diagram 2-wire technique
Connection diagram 3-wire technique
Replacing an ISH1030 or TTS1 by an ISH3030
The floor push-button have to be connected always to the a-wire.
In case of a parallel circuit both telephones have to be replaced by the ISH3030.
Commissioning
Install the devices of the system voltage-free and completely.
Proof the a-, b- and P-wire against each other on short-circuit.
Switch on the main voltage.
Note:
If the floor push-button is not working, proof, i fit is connected to the a-wire of the power
supply and control unit.
Settings
Pre-adjusted times
communication time
max. 2 min
flashing period of the green LED, if the voice
channal is busy after lifting the handset
2 sec
3 x flashing
internal standby time, if the device is calling or
is called
around
30 sec